![Rosslare InteliDoor AC-Q41H Instruction Manual Download Page 14](http://html1.mh-extra.com/html/rosslare/intelidoor-ac-q41h/intelidoor-ac-q41h_instruction-manual_1489307014.webp)
Page 26
07/04
AC-Q41H
Page 27
07/04
AC-Q41H
Setting Fail Safe/Secure Operation
Setting Tamper Siren Time
Setting the Lock Strike Release Time
The default factory setting is 0004.
The Tamper Siren feature requires the BL-D40 External Sounder.
1)
Enter Programming Mode
2)
Press
"6"
to enter
Menu 6
l
The Mode LED will flash green
3)
Construct the 4-digit code
using the instructions below:
First Digit
For Fail Secure Operation the first
digit should be
"0"
For Fail Safe Operation the first
digit should be
"1"
Second Digit
Tamper Siren Time, enter any
number from 0 to 9 minutes.
Third and Fourth Digit
Enter the number of seconds from
(1 to 99 seconds) that you want
the Lock Strike to be released.
For example 0 5 1 2 means Fail Secure Operation, with a 5
minute Tamper Siren Time, and a 12 second Lock Strike release
time.
4)
System returns to Normal Mode
l
You will hear three beeps
l
The Door LED will turn off.
l
The Mode LED will turn green
Mode
Door
GREEN
Mode
Door
GREEN
Mode
Door
GREEN
GREEN
?
?
?
?
a)
Disable Bypass Code - Disable Door Chime
Enter the 4-digit code 0000
b)
Disable Bypass Code - Enable Door Chime
Enter the 4-digit code 0001
c)
Enable Bypass Code - Disable Door Chime
Enter any 4-digit code ending with 0
d)
Enable Bypass Code - Enable Door Chime
Enter any 4-digit code not ending with 0
4)
System returns to Normal Mode
l
You will hear three beeps
l
The Door LED will turn off
l
The Mode LED will turn green
Note:
- The chime is only generated when the Lock
Strike Relay is activated due to a valid code entry.
Mode
Door
GREEN
0
0
0
1
0
0
0
0
?
?
?
0
?
?
?
0