Programming the AC-C31V 

AC-C31V Installation Manual

Page 17 

 

12.

 

Programming the AC-C31V 

You can program the AC-C31V solely via the unit's keypad-driven 

Programming Menu System. To reach the Programming Menu 

System, first place the AC-C31V into Programming Mode (see 

Entering Programming Mode for more information).  
During the AC-C31V manufacturing process, certain codes and 
settings are preprogrammed. These settings are called the 

"Default Factory Settings".  
The table below shows the names of all the AC-C31V Menus. It 

also shows all the AC-C31V default factory codes and settings. 

Table 1: Programming Menu 

Menu  
Number 

Menu  
Description 

Factory 
 Settings 

Change Open Code 1  

2580 

Change Open Code 2 

0852  

Change Program Code 

1234 

Change Normal/Secure Code 

3838 

5 Change 

Normal/Bypass 

Code 

N/A 

Change Door Release Time 

0004 

7 Enroll 

PIN 

Code 

 

Delete PIN Code 

 

Return to Default Factory Setting  

 

A complete description and instructions for each of the above 

menu items is detailed on the following pages. 

Summary of Contents for AC-C31V

Page 1: ...AC C31V Stand Alone Access Control Unit Installation Manual October 2009 ...

Page 2: ......

Page 3: ...n 11 8 Changing the Modes of Operation 12 8 1 Changing from Normal to Secure Mode 12 8 2 Changing from Secure to Normal Mode 12 8 3 Changing from Normal to Bypass Mode 12 8 4 Changing from Bypass Mode to Normal Mode 13 9 The Request to Exit REX Button 14 10 Case Tamper 15 11 The BL D40 External Sounder 16 12 Programming the AC C31V 17 12 1 Entering Programming Mode 18 12 2 Exiting Programming Mode...

Page 4: ...ting Fail Safe Secure Operation Tamper Siren Time and Lock Strike Release Time 22 12 9 Enrolling Primary and Secondary Codes 23 12 10 Deleting Primary and Secondary Codes 25 12 11 Return to Factory Default Settings 27 12 12 Replacing a Lost Programming Code 28 12 13 Replacing a Lost Normal Secure Code 28 Appendix A Limited Warranty 29 Appendix B Technical Support 31 ...

Page 5: ... and Operating Instructions 1 2 Additional Equipment The following additional equipment is required Electric Lock Strike Mechanism Fail Safe Power to Lock or Fail Secure Power to Open Power Supply with Backup Battery 12 to 24V DC AC from a regulated power supply Request to Exit REX button Normally Open Type Switch is closed when pressed BL D40 External Sounder optional Provides siren bell and chim...

Page 6: ...attached devices Max 80mA excluding attached devices Relay Outputs Lock Strike Relay 2A form C with built in suppressor protection Inputs REX N O Dry Contact LEDs Two tri colored LEDs Environmental Characteristics Operating Temperature 32 F to 145 F 0 C to 63 C Operating Humidity 0 to 95 Non Condensing Mechanical Characteristics Dimensions Length x Width x Depth 5 12 x 1 65 x 0 7 Inch 130 x 42 x 1...

Page 7: ...l User Secure User Master User Three Modes of Operation Normal Mode Bypass Mode Secure Mode Code Search feature simplifies maintaining user codes Input for Request to Exit REX button Lock Strike Electronic Relay with built in suppressor protection Comes with mounting template for easier installation Built in Case Tamper Bell Chime Siren and Strobe features available with BL D40 Programmable Siren ...

Page 8: ...V see Figure 1 3 Screw the AC C31V controller onto a US Gang Box through the two Mounting Holes provided see Figure 2 4 Pass the wires through the exit entry holes and attach them to the controller s terminal blocks as shown in the wiring diagrams See Figure 3 and Figure 4 in Wiring Diagrams for wiring diagrams of common installations 5 Replace the controller s bezel and replace the factory defaul...

Page 9: ...Installation AC C31V Installation Manual Page 7 Figure 1 AC C31V Controller Labeled Diagram ...

Page 10: ...ller Mounting Holes and Terminal Blocks 4 2 Wiring Two of the typical wiring diagrams are illustrated below see Figure 3 and Figure 4 in Wiring Diagrams For other wiring diagram examples refer to the support section of the Rosslare Web Site Http www rosslare com hk support ...

Page 11: ...Wiring Diagrams AC C31V Installation Manual Page 9 5 Wiring Diagrams Figure 3 Wiring the Lock Strike Relay and REX Figure 4 Wiring the BL D40 External Sounder ...

Page 12: ...y has a Primary Code and is only granted access when the AC C31V is in Normal or Bypass mode Secure User A Secure User must have a Primary and Secondary Code programmed the two codes must not be the same The Secure User can gain access when the AC C31V is in any of its three modes of operation In Normal mode the Secure User must use a Primary Code to gain entry In Secure Mode the Secure User must ...

Page 13: ...ller s Lock Strike Relay is programmed for Fail Safe Operation or for Fail Secure Operation When the Lock Strike Relay is programmed for Fail Secure Operation the door is locked until the Door Bell Button is pressed When the Lock Strike Relay is programmed for Fail Safe Operation the door is constantly unlocked Secure mode Mode LED is red Only Secure and Master Users can access the premises during...

Page 14: ...de The Mode LED flashes red 2 Press the key to confirm the mode change The Mode LED turns red 8 2 Changing from Secure to Normal Mode For the Secure Mode the Mode LED is red 1 The default factory setting for the Normal Secure Code is 3838 2 Enter the 4 digit Normal Secure Code The Mode LED flashes green 3 Press the key to confirm the mode change The Mode LED turns green 8 3 Changing from Normal to...

Page 15: ...shes orange 2 Press the key to confirm the mode change The Mode LED turns orange 8 4 Changing from Bypass Mode to Normal Mode For the Bypass Mode the Mode LED is orange See Changing the Normal Bypass Code and Door Chime Settings to create modify the Normal Bypass Code 1 Enter the 4 digit Normal Bypass Code Mode LED flashes green 2 Press the key to confirm the mode change Mode LED turns green ...

Page 16: ...or Fail Safe Operation or for Fail Secure Operation The door chime in the BL D40 does not sound when the REX Button is used to open the door Fail Secure Operation From the moment the REX Button is pressed the door remains unlocked until the Lock Strike Release Time has passed After this time the door is locked even if the REX Button has not been released Fail Safe Operation From the moment the REX...

Page 17: ...es receives a Tamper Event Signal it activates a Siren and if available a Strobe Light The Siren time can be easily programmed in the AC C31V from zero to nine minutes You can clear a tamper event by entering a valid User or Open Code to open the Lock Strike Output in the current Mode of Operation For example while in Secure Mode you cannot use the Open Code to clear the tamper event because the O...

Page 18: ...sounds when the controller s doorbell button is pressed The Door Chime can be programmed to sound whenever the controller unlocks the door the Door Chime does not sound when the REX Button is used to open the door The Siren can be programmed to sound when the case of the controller is opened or when the controller is removed from the wall The controller can also program the length of the Siren in ...

Page 19: ...se settings are called the Default Factory Settings The table below shows the names of all the AC C31V Menus It also shows all the AC C31V default factory codes and settings Table 1 Programming Menu Menu Number Menu Description Factory Settings 1 Change Open Code 1 2580 2 Change Open Code 2 0852 3 Change Program Code 1234 4 Change Normal Secure Code 3838 5 Change Normal Bypass Code N A 6 Change Do...

Page 20: ...ing Code is 1234 If a Programming Code is not entered within five seconds the AC C31V returns to Normal Mode 12 2 Exiting Programming Mode To exit the Programming Mode at any time Press the key for two seconds Three beeps are emitted The Door LED turns off The Mode LED turns green indicating that the AC C31V has returned to Normal Mode Note Wrong entries may reset the controller back to Normal Mod...

Page 21: ...s red 3 Enter the new 4 digit code that you want to set as Open Code 1 The system returns to Normal Mode o The Door LED turns off o The Mode LED turns green Note Open Code 1 does not function in Secure Mode Wrong entries return the controller to Normal Mode Code 0000 erases and deactivates the Open Code 12 4 Changing Open Code 2 Open Code 2 is mainly used as a method to quickly test the Lock Strik...

Page 22: ...function in Secure Mode Wrong entries return the controller to Normal Mode Code 0000 erases and deactivates the Open Code 12 5 Changing the Programming Code 1 Enter Programming Mode 2 Press 3 to enter Menu 3 The Mode LED turns green 3 Enter the new 4 digit code that you want to set as the Programming Code The system returns to Normal Mode o Three beeps are emitted o The Door LED turns off o The Mo...

Page 23: ...een 12 7 Changing the Normal Bypass Code and Door Chime Settings The Normal Bypass Code is also used to turn the Door Chime off and on 1 Enter Programming Mode 2 Press 5 to enter Menu 5 The Mode LED flashes orange 3 Program the Normal Bypass Code and Door Chime in one of the following four different ways o Disable the Bypass Mode and disable the Door Chime Enter the 4 digit code 0000 o Disable the...

Page 24: ...ramming Mode 2 Press 6 to enter Menu 6 The Mode LED flashes green 3 Construct the 4 digit code using the following instructions o First digit For Fail Secure Operation enter a 0 For Fail Safe Operation enter a 1 o Second digit Tamper Siren Time enter the number of minutes from 1 to 9 o Third and fourth digits Lock Strike Release Time enter the number of seconds from 1 to 99 after which you want th...

Page 25: ...have to be unique meaning that multiple users can all hold the same Secondary Code Secondary Codes cannot be the same as any system codes such as the Normal Secure Code or Open Code Users who hold Secondary Codes can gain entry in any Mode of Operation 12 9 3 Enrolling Primary and Secondary Codes There are two methods to enroll Primary and Secondary codes The Standard Method Mainly used when the U...

Page 26: ...already has a Primary Code but does not have a Secondary Code the Mode LED flashes red indicating that the controller is ready to accept a Secondary Code o If the selected slot already has a Primary and Secondary Code a long beep is emitted and the controller returns to Normal Mode 4 Enter the 4 digit PIN that you want to assign as the Primary or Secondary Code for this slot number 5 If the PIN en...

Page 27: ...onging to the user for whom you want to add a Secondary Code The Mode LED flashes red If the Primary Code entered is not valid a long beep is emitted and the AC C31V continues to wait for a valid Primary Code 5 Enter the 4 digit PIN Code to be used as the Secondary Code o If the Secondary Code is valid the controller beeps three times and returns to Normal Mode o If the Secondary Code is invalid t...

Page 28: ...s to Normal Mode 4 Enter your Programming Code to confirm the deletion o If the Programming Code is valid three beeps are emitted and the AC C31V returns to Normal Mode o If the Programming Code is invalid a long beep is emitted and the AC C31V returns to Normal Mode Note It is recommended that a record be kept of added and deleted users so that it is easier to keep track of which user slots are e...

Page 29: ...kept of added and deleted users so that it is easier to keep track of which user slots are empty and which user slots are not 12 11 Return to Factory Default Settings WARNING Be very careful before using this command as it will erase the entire memory including all User and Special Codes and will return all codes to their factory default settings 1 Enter Programming Mode 2 Press 0 to enter Menu 0 ...

Page 30: ...into the unit using the initial default code 1234 You have 15 seconds to do so before the controller reverts to the existing code 12 13 Replacing a Lost Normal Secure Code Note In order to be able to replace lost normal secure code the AC C31V must be in Secure Mode Before proceeding verify that the Mode LED is red 1 Remove power from the AC C31V 2 Press the REX button 3 Apply power to the unit wh...

Page 31: ...warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested at ROSSLARE E...

Page 32: ...the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be l...

Page 33: ...ty com United States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Africa Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martinez Buen...

Page 34: ......

Page 35: ...0706 0960340 00 www rosslaresecurity com ...

Reviews: