Programming the AC-C31V
AC-C31V Installation Manual
Page 22
o
Enable the Bypass Mode and
enable the Door Chime:
Enter any 4-digit code not ending with
0
.
The system returns to Normal Mode:
o
Three beeps are emitted.
o
The Door LED turns off.
o
The Mode LED turns green.
Note:
The Door is only generated when the Lock Strike Relay is
activated due to a valid code entry.
12.8
Setting Fail Safe/Secure Operation, Tamper
Siren Time, and Lock Strike Release Time
1. Enter Programming Mode.
2. Press "6" to enter Menu 6.
The Mode LED flashes green.
3. Construct the 4-digit code using the
following instructions.
o
First digit: For Fail Secure Operation,
enter a
"0"
; For Fail Safe Operation, enter a
"1".
o
Second digit: Tamper Siren Time; enter the number of
minutes (from
"1
" to
"9")
.
o
Third and fourth digits: Lock Strike Release Time; enter the
number of seconds (from
"1"
to
"99"
) after which you want
the Lock Strike to be released.
For example:
0 5 1 2
means Fail Secure Operation, with a 5
minute Tamper Siren Time, and a 12 second Lock Strike
Release Time.
The system returns to Normal Mode:
o
Three beeps are emitted.
o
The Door LED turns off.
o