![Ross carbonite Operation Manual Download Page 18](http://html1.mh-extra.com/html/ross/carbonite/carbonite_operation-manual_1489006018.webp)
Figure 9: Re-Entry for MiniME
™
Mode Timing Windows
To Re-Enter an ME
1.
Set up ME 1 with a background and a key.
Figure 10: ME 1
2.
Set up ME 2 with a key.
Figure 11: ME 2
3.
Select ME 1 as a source on the Background Bus
of ME 2. Notice that the output of ME 1 is now
being used as the background of ME 2.
Figure 12: ME 1 Re-entered onto ME 2
FlexiClean Clean Feed
FlexiClean provides a second program output that is
derived from a different location than the standard
program output. A frequent application is the recording
of shows for later airing without call-in phone numbers
inserted.
The clean feed output can come from before or between
the keyers.
KEY 1
KEY 2
PGM/
PST
KEY 3
PGM
CLEAN
FEED
KEY 4
Figure 13: Clean Feed Modes
Video Preview
Video preview allows you to use an additional monitor
to preview what the next shot is going to be. The preview
for an ME shows what is selected for the next transition
on that ME. This includes the keys and background video
sources that will be on-air after the next transition.
MultiViewer
Each MultiViewer generator allows you to view up to
16 video sources, in 32 different layouts, from a single
output BNC. Any video source on the switcher, including
ME 1 and ME 2 Program, Preview, and Media-Store
channels, can be assigned to any box on the MultiViewer
output. All boxes on the MultiViewer output include
mnemonic source names and red and green tallies.
If the switcher is operating in a standard-definition video
format, the MultiViewer can be set to output
high-definition. In HD output mode, the MultiViewer is
only available on specific output BNCs and only supports
29 different layouts.
ME Copy
You can copy the entire contents of an ME to another
keyer in the same, or a different ME. The entire contents
of the destination ME is replaced with the contents of
the source ME.
When you copy an ME, the switcher tries to assign
resources to the destination ME to match the source ME.
If these resources are not available, the switcher may
need to steal resources. If you are performing the copy
from the control panel you will be asked to confirm the
stealing of any required resources. From DashBoard you
will not be asked and the required resources will be
stolen.
Note:
If you copy from the half ME to a full ME, keys 3 and 4
are defaulted.
18