Network Connections
The control panel connects to the frame in one of three
ways, depending on the model of control panel or
option you have.
•
Carbonite Black
— panel connects to the frame
over a standard ethernet connection
•
CarboNET
— panel connects to the CarboNET
over a serial connection and the CarboNET
connects to the frame over a standard ethernet
connection
•
Carbonite
— panel connects to the frame over a
serial connection (Panel to Frame port)
The ethernet connection from the frame is also used to
upload stills to the Media-Store channels, download
switcher data files, or control switcher functions using
DashBoard.
The switcher uses the following network ports:
•
FTP
— 21
•
SSH
— 21
•
DashBoard
— 5253
•
SLP
— 427
•
Web Server
— 80
•
RossTalk
— 7788
Frame Network Setup (Ethernet)
If you are connecting to the frame over ethernet you
must use DashBoard to set the IP address of the frame.
The frame comes from the factory set with a static IP
address (192.168.0.123) but can be set to use DHCP to
automatically obtain an IP address.
Note:
If you use a DHCP server, it must be set to always give
the frame the same IP address. DashBoard, the Carbonite
Black control panel, and CarboNET need a fixed IP address to
connect to.
Tip:
If you do not know the IP address of the frame, you
can set DIP switch 3 on the frame to lock the IP address to
192.168.0.123. The frame must be re-started for the new IP
address to be applied.
Connecting to the Switcher from DashBoard
DashBoard should automatically detect and connect
to the frame once it is connected to the same subnet.
If you have trouble discovering the switcher frame,
or it is located on another subnet, you can manually
connect DashBoard to the switcher to establish
communications. Once connected, DashBoard will
remember the connection until you remove it.
To Manually Connect to the Frame To
Connect to the Frame
You need the IP address of the frame to connect to it
manually from DashBoard.
1.
Click
File
>
New
>
Manual Connection
.
2.
In the
IP Address
field, enter the IP address
of the switcher frame. The default IP address is
192.168.0.123.
Tip:
If the control panel is connected to the frame over
a serial link, the IP address can be found through the
menu system (Press
MENU
>
System
>
NEXT
>
NEXT
>
FrmIP Addr
).
3.
Click
Detect Settings
.
4.
Click
Finish
.
The frame appears in the
Tree View
.
To Change the IP Address
1.
Click
Navigation Menu
>
Configuration
>
Network
.
2.
Enter a name in the
Switcher Name
field.
This is the name that appears in the tree view in
DashBoard.
3.
Click
Edit
.
4.
Click an
ETH
X
Mode
button to set that network
port to use DHCP (
DHCP
), or a static IP address
(
Static
).
5.
For a static IP address, enter the IP address
(
ETH
X
IP Address
), subnet mask (
ETH
X
Subnet Mask
), and gateway (
Gateway
) you
want to use.
6.
Click
Update
.
Frame Network Setup (Serial)
If you are connecting to the frame over a serial
connection (Carbonite) you can use the control panel to
initially configure the network settings for the frame.
To Set an IP Address Using DHCP
Due to the nature of DHCP, your switcher may get a
different IP address each time it is powered on or re-
connected to a network. You must have the switcher
connected to a network to be able to obtain an IP
address using DHCP.
Note:
Ensure that DIP switch 3 on the frame is set in the up
position. If this DIP switch is set in the down position, the IP
address is fixed at 192.168.0.123. Ensure that DIP switch 3
on the frame is set in the up position. If this DIP switch is set in
the down position, the IP address is fixed at 192.168.0.123.
1.
Press
MENU
>
System
>
NEXT
>
NEXT
>
FrmIP Addr
.
14
• Network Connections — Carbonite Black Setup Manual (v14.0)