![Ross Abekas Tria+ UHD User Manual Download Page 60](http://html1.mh-extra.com/html/ross/abekas-tria-uhd/abekas-tria-uhd_user-manual_1488988060.webp)
2.
Click the
RS422
tab.
3.
Click
Room
X
Configuration
and select the room you want to configure. Later you will assign this room to a
channel.
4.
In the
RS422 Protocol
area, select
AMP
.
5.
In the
Response Time
area, select how quickly the server executes the Clip Play command after the Clip Load
command.
•
Fast
— executes the play command immediately after the load command. This is recommended when
controlling the server from an external switcher.
•
Accurate
— executes the play command only after receiving confirmation that the clip has loaded. This is
recommended when controlling the server from an automation system.
6.
In the
Edit Timing
area, select a timing offset for when you are controlling the server from an external editor over
serial.
•
Timecode Alignment
— select the offset, in frames, of the timecode information that is sent to the editor
during playout or record.
•
Source Alignment
— select the offset, in frames, of the timecode information that is sent to the editor during
playout.
•
Out Point Offset
— select the offset, in fields, of the out-point timecode value that is sent to the editor during
record.
7.
In the
Video Edit Effect
area, select which tracks get recorded when an external editor issues the Video Record
command to the server.
•
Edit Video Track
— only the video track is recorded.
•
Edit Key Track
— only the alpha (key) track is recorded.
•
Edit Video and Key Tracks
— both the video and alpha (key) tracks are recorded. The clip loaded into the
VKA channel transport must have an alpha track.
60
• Remote Control Support — Tria+ UHD User Manual