Reference Manual
00809-0100-4727, Rev EA
October 2010
A-5
Rosemount 8700 Series
E-SERIES
PERFORMANCE
SPECIFICATIONS
(System specifications are given using the frequency output and with the unit
at reference conditions.)
Accuracy
Includes the combined effects of linearity, hysteresis, repeatability, and
calibration uncertainty.
Rosemount E Series with 8705/8707 Sensor:
Standard system accuracy is ±0.25% of rate ±1.0 mm/sec from 0.04 to 6
ft./s (0.01 to 2 m/s); above 6 ft./s (2 m/s), the system has an accuracy of
±0.25% of rate ±1.5 mm/sec.
Optional high accuracy is ±0.15% of rate ±1.0 mm/sec from 0.04 to 13 ft./s
(0.01 to 4 m/s); above 13 ft./s (4 m/s), the system has an accuracy of
±0.18% of rate.
(1)
Rosemount E-Series with 8711 Sensor:
Standard system accuracy is ±0.25% of rate ±2.0 mm/sec from 0.04 to 39
ft./s (0.01 to 12 m/s).
Optional high accuracy is ±0.15% of rate ±1.0 mm/sec from 0.04 to 13 ft./s
(0.01 to 4 m/s); above 13 ft./s (4 m/s), the system has an accuracy of
±0.18% of rate.
Rosemount E-Series with 8721 Sensor:
Standard system accuracy is ±0.5% of rate from 1 to 39 ft./s (0.3 to 12
m/s); between 0.04 and 1.0 ft./s (0.01 and 0.3 m/s), the system has an
accuracy of ±0.005 ft./s (0.0015 m/s).
(1)
For Sensor sizes greater than 12 in. (300 mm) the high accuracy is ±0.25% of rate from 3 to
39 ft./sec (1 to 12 m/sec).
0
0.5
0.5
1.0
1.0
1.5
1.5
2.0
2.0
2.5
2.5
0
3
3
(1)
(1)
6
6
(2)
(2)
13
13
(4)
(4)
20
20
(6)
(6)
27
27
(8)
(8)
33
33
(10)
(10)
40
40
(12)
(12)
Velocity in ft/s (m/s)
Velocity in ft/s (m/s)
% of Rate
0.25%
0.25%
0.15%
0.15%
0
0.5
0.5
1.0
1.0
1.5
1.5
2.0
2.0
2.5
2.5
0
3
3
(1)
(1)
6
6
(2)
(2)
13
13
(4)
(4)
20
20
(6)
(6)
27
27
(8)
(8)
33
33
(10)
(10)
40
40
(12)
(12)
Velocity in ft/s (m/s)
Velocity in ft/s (m/s)
% of Rate% of Rate
0.25%
0.25%
0.15%
0.15%
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
+86-755-8660-6182