Reference Manual
00809-0100-4727, Rev EA
October 2010
A-39
Rosemount 8700 Series
Options
(Include with selected model number)
Certifications
Standard
Standard
CR
(17)
Canadian Registration Number (CRN) certification
•
•
★
PD
Pressure Equipment Directive Certification (PED, per 97/23/EC)
•
•
★
Expanded
DW
NSF Drinking Water Certification
(18)
•
•
Optional Grounding Rings
(19)
Standard
Standard
G1
(2) 316L SST Ground Rings
•
•
★
G2
(2) Nickel Alloy 276 (UNS N10276) Ground Rings
(20)
•
•
★
G5
(1) 316L SST Ground Rings
•
•
★
G6
(1) Nickel Alloy 276 (UNS N10276) Ground Rings
•
•
★
Expanded
G3
(2) Titanium Ground Rings
•
•
G4
(2) Tantalum Ground Rings
(21)
•
•
G7
(1) Titanium Ground Rings
•
•
G8
(1) Tantalum Ground Rings
•
•
Optional Lining Protectors
Expanded
L1
(2) 316L SST Lining Protectors
•
•
L2
(2) Nickel Alloy 276 (UNS N10276) Lining Protectors
•
•
Expanded
L3
(2) Titanium Lining Protectors
•
•
H1
Lay-length matching 8701 using spool piece
•
•
H2
Lay-length matching 8701
(22)
•
•
H5
Lay-length matching Foxboro 2800 using spool piece
(23)
•
•
H7
Lay-length ABB CopaX and MagX using spool piece
•
•
Other Options
Standard
Standard
B3
Integral Mount with 8732
•
★
J1
CM 20 Conduit Adapter
•
•
★
Expanded
D1
High Accuracy Calibration (0.15% of rate for matched sensor and E-Series
transmitter)
(24)
(0.25% of rate for matched 8707 and 8712H)
•
•
DT
Heavy Duty Tagging
•
•
J2
PG 13.5 Conduit Adapter
•
•
SC
304 SST Junction Box, fully welded to housing
•
•
8705
8707
TA
High Temperature Permeable Fluid Option (Contains vent holes provided
for permeable fluids such as nitric acid, hydrofluoric acid, or sodium
hydroxide at high temperatures)
•
•
Q4
Calibration Certificate per ISO 10474 3.1B
•
•
Q8
Material Traceability 3.1B
•
•
Q9
Material Traceability Electrode only 3.1B
•
•
Q66
Welding Procedure Qualification Record Documentation
•
•
Q67
Welding Performance Qualification Record Documentation
•
•
Q70
Weld Examination Inspection Certificate, ISO 10474 3.1B
•
•
Typical Model Number: 8705 T SA 040 C1 W0 N0
(1) The high-signal magmeter system is not currently available with CE mark.
(2) Available in
1
/
2
-in. to 36-in. line sizes ANSI 150, ANSI 300, and DIN Flanges. Available in 1-in. to 10-in. ANSI 600 Derated only.
Table 2. Rosemount Flanged Sensor Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
+86-755-8660-6182