![Rosemount Series 8700 Reference Manual Download Page 101](http://html1.mh-extra.com/html/rosemount/series-8700/series-8700_reference-manual_1487425101.webp)
Reference Manual
00809-0100-4727, Rev EA
October 2010
B-9
Rosemount 8700 Series
Table B-5. Electrical Data
Table B-6. Relation between ambient temperature, process temperature, and temperature class
(1)
Table B-7. Relation between the maximum ambient temperature, the maximum process temperature,
and the temperature class
(2)
Rosemount 8732 Flow Transmitter
Power supply:
250 V AC, 1 A or 42 V DC, 1 A, 20 W maximum
Pulsed output circuit:
30 V DC (pulsed), 0,25 A, 7,5 W maximum
4-20 mA output circuit:
30 V DC, 30 mA, 900 mW maximum
Rosemount 8705 and 8711 Sensors
Coil excitation circuit:
40 V 0,5 A, 20 W maximum
Electrode circuit:
in type of explosion protection intrinsic safety EEx ia IIC, U
i
= 5 V, l
i
= 0.2 mA, P
i
= 1 mW, U
m
= 250 V
Meter Size (Inches) Maximum Ambient Temperature
Maximum Process Temperature
Temperature Class
1
/
2
149°F (65°C)
239°F (115°C)
T3
1
149°F (65°C)
248°F (120°C)
T3
1
95°F (35°C)
95°F (35°C)
T4
1
1
/
2
149°F (65°C)
257°F (125°C)
T3
1
1
/
2
122°F (50°C)
148°F (60°C)
T4
2
149°F (65°C)
257°F (125°C)
T3
2
149°F (65°C)
167°F (75°C)
T4
2
104°F (40°C)
104°F (40°C)
T5
3 - 4
149°F (65°C)
266°F (130°C)
T3
3 - 4
149°F (65°C)
194°F (90°C)
T4
3 - 4
131°F (55°C)
131°F (55°C)
T5
3 - 4
104°F (40°C)
104°F (40°C)
T6
6
149°F (65°C)
275°F(135°C)
T3
6
149°F (65°C)
230°F (110°C)
T4
6
149°F (65°C)
167°F (75°C)
T5
6
140°F (60°C)
140°F (60°C)
T6
8-60
149°F (65°C)
284°F (140°C)
T3
8-60
149°F (65°C)
239°F (115°C)
T4
8-60
149°F (65°C)
176°F (80°C)
T5
8-60
149°F (65°C)
149°F (65°C)
T6
(1) This table is applicable for the E1 and KD approval codes only.
Maximum Ambient
Temperature
Maximum process temperature °F (°C) per temperature class
T3
T4
T5
T6
0.5 in. sensor size
149°F (65°C)
297°F (147°C)
138°F (59°C)
54°F (12°C)
18°F (-8°C)
140°F (60°C)
309°F (154°C)
151°F (66°C)
66°F (19°C)
28°F (-2°C)
131°F (55°C)
322°F (161°C)
163°F (73°C)
79°F (26°C)
41°F (5°C)
122°F (50°C)
334°F (168°C)
176°F (80°C)
90°F (32°C)
54°F (12°C)
113°F (45°C)
347°F (175°C)
189°F (87°C)
102°F (39°C)
66°F (19°C)
104°F (40°C)
351°F (177°C)
199°F (93°C)
115°F (46°C)
79°F (26°C)
95°F (35°C)
351°F (177°C)
212°F (100°C)
127°F (53°C)
90°F (32°C)
86°F (30°C)
351°F (177°C)
225°F (107°C)
138°F (59°C)
102°F (39°C)
77°F (25°C)
351°F (177°C)
237°F (114°C)
151°F (66°C)
115°F (46°C)
68°F (20°C)
351°F (177°C)
248°F (120°C)
163°F (73°C)
127°F (53°C)
149°F (65°C)
318°F (159°C)
158°F (70°C)
72°F (22°C)
34°F (1°C)
140°F (60°C)
331°F (166°C)
171°F (77°C)
84°F (29°C)
46°F (8°C)
(2) This table is applicable for N1 option codes only.
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
+86-755-8660-6182