![Rosemount 5401 Reference Manual Download Page 119](http://html1.mh-extra.com/html/rosemount/5401/5401_reference-manual_1487397119.webp)
Reference Manual
00809-0100-4026, Rev FA
July 2009
7-29
Rosemount 5400 Series
Incorrect measurement level
when the product surface is
above the 50% level.
May be caused by:
• Radar echo bouncing from the
product surface to the tank roof then
back to the surface
• Strong echoes from very high
reflectivity product
Action:
• Move the transmitter from the center
of the tank roof
• Enable the
Double Bounce
function,
see “Double Bounce” on page C-5
RRM:
Setup > Advanced
Measured level jumps to a
higher value.
May be caused by:
• Foam on the product surface
• Turbulent product surface
Action:
• Enable the Tank Environment
Foam
parameter
RRM: Setup>Tank>Environment
HART: [2, 3, 2]
• Enable the Tank Environment
Turbulent Surface
parameter
RRM: Setup>Tank>Environment
HART: [2, 3, 2]
Measured level gets locked near
the top of the tank.
May be caused by:
• Antenna tip ends inside the tank
nozzle
• Disturbing objects near the antenna
• Product built up on the antenna
Action:
• Mount the transmitter on another
nozzle, if possible
• Increase the
Hold Off
distance
RRM:
Setup > Advanced
HART: [2, 3, 4]
The level value drops to a lower
value when the product surface
is close to the antenna.
May be caused by:
• Product level within the Hold Off
region, i.e. outside the approved
measuring range, and the transmitter
is picking up secondary signal
reflections
Action:
• Avoid filling the tank to levels close to
the antenna
• Move the transmitter to increase the
distance between maximum product
level and antenna, if possible
• Activate the Full Tank Handling
function if measurements up to the
antenna are required, see “Full Tank
Summary of Contents for 5401
Page 2: ......
Page 4: ......
Page 10: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series TOC 6 ...
Page 24: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 2 10 ...
Page 80: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 5 26 ...
Page 90: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 6 10 ...
Page 160: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series B 16 ...
Page 174: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series C 14 ...
Page 177: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Index 3 Rosemount 5400 Series ...
Page 178: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series Index 4 ...
Page 179: ......