Reference Manual
00809-0100-4026, Rev FA
July 2009
7-11
Rosemount 5400 Series
The View/Record Mode
Tab
The View/Record Mode tab presents a plot of the current tank conditions
where each radar echo is displayed as a peak in the signal plot.
When clicking the
Echo Curve
icon under Device Config/Tools, the
Echo
Curve Analyzer
window appears with the
View/Record Mode
tab selected:
Figure 7-9. A Echo Curve plot in
View/Record mode.
Advanced
The Advanced button opens a list below the Echo Curve plot with information
on all echoes in the tank such as signal amplitude and position in the tank.
Play
When the Play button is clicked, the tank is continuously updated without
being stored.
Record Tank Spectra
This function records tank spectra over time. This can be a useful function if,
for example, studying the tank signal when filling or emptying the tank is
desired.
File Mode Tab
The File Mode tab will open files with saved snapshots/movies to be
presented in the spectrum plot. A movie file can be played to view the
amplitude plot at the desired update rate.
Record tank spectra
Play (continuously updates the spectrum)
Summary of Contents for 5401
Page 2: ......
Page 4: ......
Page 10: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series TOC 6 ...
Page 24: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 2 10 ...
Page 80: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 5 26 ...
Page 90: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 6 10 ...
Page 160: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series B 16 ...
Page 174: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series C 14 ...
Page 177: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Index 3 Rosemount 5400 Series ...
Page 178: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series Index 4 ...
Page 179: ......