![Rosemount 485 Annubar Quick Installation Manual Download Page 9](http://html.mh-extra.com/html/rosemount/485-annubar/485-annubar_quick-installation-manual_1487394009.webp)
Quick Installation Guide
00825-0100-4809, Rev DB
December 2009
Flanged 485 Annubar
9
S
TEP
3: A
SSEMBLE
AND
C
HECK
F
IT
-
UP
For accurate measurement, use the following steps to ensure that Ports A and B are equal
distances from the inside walls of the pipe.
1. Assemble the 485 to the mounting hardware with the gaskets and bolts.
2. Hand tighten the bolts just enough to hold the position of the sensor centered in the
mounting hardware.
3. Measure the distance from the high point of the weldolet to the first sensing hole, port B,
then subtract
1
/
16
-in (1,6 mm).
4. Measure the distance from the end of the transferred length in step 4 to the last sensing
hole, port A.
5. Compare the numbers obtained in steps 3 and 4.
Small discrepancies can be compensated for with the fit-up of the mounting hardware. Large
discrepancies may cause installation problems or error.
Figure 8. Fit-up check for 485 Annubar with Opposite-Side Support
Liquid or Steam
Gas
ODF
Port B
Port A
Pipe
Outside
Diameter
The
same
within
1
/8
-in.
(3 mm)
The
same
within
1
/8
-in. (3
mm)
Pipe Outside
Diameter
Port A
Port B
ODF
0100-4809 Rev DB.fm Page 9 Wednesday, December 30, 2009 3:57 PM