![Rosemount 3144P User Manual Download Page 76](http://html1.mh-extra.com/html/rosemount/3144p/3144p_user-manual_1487451076.webp)
Reference Manual
00809-0100-4021, Rev FB
August 2011
Rosemount 3144P
4-8
F
OUNDA
TION
Fieldbus
MAINT_PRI
MAINT_PRI
designates the alarming priority of the MAINT_ALM, “Process
Alarms” on page 4-18. The default is 0 and the recommended values is 3
to 7.
MAINT_ACTIVE
The MAINT_ACTIVE
parameter displays which of the alarms is active.
Only the condition with the highest priority will be displayed. This priority is
not the same as the MAINT_PRI parameter described above. This priority
is hard coded within the device and is not user configurable.
MAINT_ALM
An alarm indicating the device needs maintenance soon. If the condition is
ignored, the device will eventually fail.
Advisory Alarms
An advisory alarm indicates informative conditions that do not have a direct
impact on the device's primary functions. There are five parameters
associated with ADVISE_ALARMS, they are described below.
ADVISE_ENABLED
The ADVISE_ENABLED
parameter contains a list of informative
conditions that do not have a direct impact on the device's primary
functions. Below is a list of the advisories with the highest priority first.
1.
NV Writes Deferred
2.
SPM Process Anomaly detected
ADVISE_MASK
The ADVISE_MASK
parameter will mask any of the failed conditions listed
in ADVISE_ENABLED. A bit on means the condition is masked from
alarming and will not be reported.
ADVISE_PRI
ADVISE_PRI
designates the alarming priority of the ADVISE_ALM, see
“Process Alarms” on page 4-18. The default is 0, and the recommended
values are 1 or 2.
ADVISE_ACTIVE
The ADVISE_ACTIVE
parameter displays the active advisories. Only the
advisory with the highest priority is displayed. This priority is not the same
as the ADVISE_PRI parameter described above, but is hard coded within
the device and is not user configurable.
ADVISE_ALM
ADVISE_ALM indicates advisory alarms. These conditions do not have a
direct impact on the process or device integrity.
Recommended Actions
for PlantWeb Alerts
RECOMMENDED_ACTION
The RECOMMENDED_ACTION parameter displays a text string that gives a
recommended course of action based on the type and specific event of the
PlantWeb alerts are active.