Orion Extender Installation and Operation Manual
65
Fiber
A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over active
network components, such as Ethernet Hubs, Matrixes or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of Cable
Specifications
Single-
mode 9μm
Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout cable)
I/AD(ZN)H 4E9 (in-house or outdoor breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with protection against rodents)
Multi-
mode 50μm
Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor breakout cable, resistant)
Multi-
mode 62.5μm
Two fibers 62.5μm
I-V(ZN)HH 2G62,5 (in-house breakout cable)
A/DQ(ZN)B2Y 4G62,5 (outdoor cable, with protection against rodents)
Table 37, Fiber Cable Specifications
Only use Single-mode connection cables for fiber connections that are based on 3G SFPs.
Maximum Acceptable Cable Length
Type of cable
Maximum Acceptable Cable Length
Single-
mode 9μm
32,800 ft (10,000 m)
Single-
mode 9μm XV
16,400 ft (5000 m)
Multi-
mode 50μm (OM3)
3,280 ft (1,000 m)
Multi-
mode 50μm
1,300 ft (400 m)
Multi-
mode 62.5μm
650 ft (200 m)
Table 38. Maximum Acceptable Fiber Cable Lengths
If single-mode SFPs are used with multi-mode fiber cables, the maximum acceptable cable length can
normally be increased.
Type of Connector:
LC Connector