Orion Extender Installation and Operation Manual
61
Serial Interface
The serial interface option supports full-duplex transmission with a real hardware handshake up to a Baud rate
of 115,200 Baud. The Receiver is wired as DTE (Data Terminal Equipment, like CPU output) and can be
connected directly to DCE devices (Data Communication Equipment).
Serial touch screens can be connected directly to the Receiver unit.
To connect to a serial printer (or other DTE device), you need a null modem cable (crossed cable)
between the Receiver Unit and the device.
Operation of several devices:
The serial interface transmits 6 signals (3 for each direction). Normally, 4 of the 6 signals are handshake
signals (in addition to RxD and TxD). The following configurations, however, can be realized using special
adapter splitting cables:
three single 2-wire transmissions
two transmissions with a handshake signal
a serial mouse and a single 2-wire transmission
In this case, choose XON / XOFF software handshake for traffic control at printer and PC
.
Connection Format
DTE (Data Terminal Equipment)
Speed
Up to 115,200 baud
Data Format
Format independent
Data Transmission
RxD (Receive Data)
TxD (Transmit Data)
Traffic Control
The following signals are transmitted (handshake):
RTS (Request To Send)
CTS (Clear To Send)
DTR (Data Terminal Ready)
DSR (Data Set Ready)
Table 30. Serial Interface Specifications
RS422 Serial Interface
Orion Xtenders with a RS422 serial interface (D-Sub 9) support a differential full duplex transmission up to a
Baud rate of 115,200 Baud. The Transmitter is designed as controlling device, and so can be connected
directly to video or media servers. The Receiver is designed as a controlled device, and so can be connected
directly to remote controllers.
Connection Format
Sony Standard
Speed
Up to 115,200 baud
Data Format
Format independent
Traffic Control
RX+ (Receive Data)
RX- (Receive Data)
TX+ (Transmit Data)
TX- (Transmit Data)
Table 31. RS422 Serial Interface Specifications
Note:
The serial interface only supports one connected device per upgrade module.