Galaxy 65 Troubleshooting
61
Warning
Whenever replacing a module NEVER leave an EMPTY space in the rear of the enclosure, obtain
a replacement before removing the problem part.
7.3 Audible Alarm
The Ops Panel also includes an Audible Alarm which indicates when a fault state is present. The following
conditions will activate the Audible Alarm:
• Drive Fault
• Fan Fault
• Voltage out of range
• Over temperature
• Thermal overrun
• System fault
7.3.1 Audible Alarm Mute
When the Audible Alarm sounds, it may be muted by pressing the Alarm Mute push-button. Automatic
muting will take place after two minutes if the mute switch is not manually operated. The Alarm Mute
push-button is located above the indicators on the Ops Panel (see
Figure 7–1
).
When the alarm is muted it will continue to sound with short intermittent bleeps to indicate that a problem
still exists, It will be silenced when all problems are cleared.
LED Test Mode
The Alarm Mute push-button can also be used to test the LEDs on the Ops Panel. When the Mute push-
button is held, all LEDs will be illuminated if there are no faults present.
Figure 7–1
Ops Panel
Summary of Contents for The Galaxy 65
Page 1: ...Galaxy 65 User Guide Part No 43061 02A Issue 2 0 January 13 2004...
Page 9: ...Contents ix Index 229...
Page 10: ...x Galaxy 65 User Guide...
Page 19: ...Preface xvii...
Page 20: ...Galaxy 65 User Guide xviii...
Page 52: ...Galaxy 65 User Guide 32...
Page 58: ...Galaxy 65 User Guide 38...
Page 72: ...Galaxy 65 User Guide 52...
Page 114: ...Galaxy 65 User Guide 94...
Page 172: ...Galaxy 65 User Guide 152...
Page 192: ...Galaxy 65 User Guide 172...
Page 208: ...Galaxy 65 User Guide 188...
Page 240: ...Galaxy 65 User Guide 220...
Page 248: ...Galaxy 65 User Guide 228...