![Rorke Data The Galaxy 65 User Manual Download Page 190](http://html1.mh-extra.com/html/rorke-data/the-galaxy-65/the-galaxy-65_user-manual_1486225190.webp)
Galaxy 65 User Guide
170
4
Select
Enabled
and press
Enter
.
The Rescan Rate screen displays.
5
Enter the rescan rate in minutes.
This tells the SM how often it should look for an available drive by rescanning the bus. Rescanning the
bus frequently can affect performance. If you have an EMP, the dynamic spare configuration will not
rescan the bus. The EMP will detect the new drive and tell the SM to rescan; the rescan rate you set here
will not affect the system.
The system confirms the change.
6
Select
Yes
and press
Enter
.
E.3 Managing the Spare Pool
The spare pool lets you have one or more disk drives available for the reconstruction of redundant arrays
(mirrored [RAID 1 and RAID 10] and parity [RAID 3, RAID 4, RAID 5, and RAID 50]). Once you assign a
drive to the spare pool, it is not available for use as an array member or as a dedicated spare.
Pool spares are available to both SMs. If a drive in an array on either SM fails, the SM can use a pool
spare to reconstruct the array.
If a pool spare is too small (smaller than an individual member in an array), the SM cannot use it.
Summary of Contents for The Galaxy 65
Page 1: ...Galaxy 65 User Guide Part No 43061 02A Issue 2 0 January 13 2004...
Page 9: ...Contents ix Index 229...
Page 10: ...x Galaxy 65 User Guide...
Page 19: ...Preface xvii...
Page 20: ...Galaxy 65 User Guide xviii...
Page 52: ...Galaxy 65 User Guide 32...
Page 58: ...Galaxy 65 User Guide 38...
Page 72: ...Galaxy 65 User Guide 52...
Page 114: ...Galaxy 65 User Guide 94...
Page 172: ...Galaxy 65 User Guide 152...
Page 192: ...Galaxy 65 User Guide 172...
Page 208: ...Galaxy 65 User Guide 188...
Page 240: ...Galaxy 65 User Guide 220...
Page 248: ...Galaxy 65 User Guide 228...