15
1
USINT
Temperature OK bit
Active when
Tact=Tset
Off (0),
active when
Tact=Tset (1),
active when
Tact=Tset with
latch (2)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 0F 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC6
6
USINT
Data length
1
16
1
USINT
Hold mode
Off
Off (0), on (1), 2 s
(2)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 10 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC6
6
USINT
Data length
1
17
1
SINT
Calibration temperature, channel 1
20 °C
-1 (= variable),
0…40 °C
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 11 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC2
6
USINT
Data length
1
18
1
UINT
Temperature coefficient, channel 1
1100 ppm/K
400…4000 ppm/K
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 12 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC7
6
USINT
Data length
2
Instance
Attri-
bute ID
Data
type
1
Name
Default
value
Value range