Startup and operation
Page 18
RES-5011
Version 2
Each time the heatsealing band is replaced, you must calibrate the zero point with the AUTOCAL function while
the band (and the environment, i.e. silicone, PTFE cover, sealing bar etc.) is still cold in order to compensate pro-
duction-related resistance tolerances.
If a new heating element is used, the above-described procedure for burning in must be performed.
7.4
Startup procedure
Please also refer to section 2 "General information" on page 3 and section 3 "Use" on page 6.
Mounting, installation and startup may only be performed by authorized persons who have received
suitable instruction and are familiar with the associated risks and warranty provisions.
7.4.1
Initial startup
Condition: The device must be correctly installed and connected (
section 6 "Mounting and installation" on
page 8).
Proceed as follows to start up the controller for the first time:
1. Switch off the line voltage and the 24 VDC supply, and verify that the circuit is de-energized.
2. Set the IP address of the device either by means of the rotary coding switches or a DHCP server (
"Device configuration" on page 15).
3. Link the device description file (EDS) into the EtherNet/IP
TM
scanner (
section 8.3), then select the required
parameters, make the connections, assign an IP address, and start the communication.
4. Make sure that the higher-level controller does not send values not equal to zero to the temperature controller.
5. Switch on the line voltage and the 24 VDC supply (the order is arbitrary).
6. When the voltage is switched on, the yellow "AUTOCAL" LED lights up for approximately 0.3 seconds to indi-
cate that the controller is being powered up correctly.
If the red "ALARM" LED lights up for 0.3…1.5 seconds when the voltage is switched on in addition
to the yellow "AUTOCAL" LED, the configuration of this controller has been changed in the visual-
ization software (
section 8.12 "USB interface for visualization software ROPEXvisual
order to avoid malfunctions, please check the controller configuration before continuing the startup pro-
cedure.
7. One of the following states then appears:
8. Activate the AUTOCAL function while the heatsealing band is still cold by setting the AC bit (
A
UTO
C
AL) in the
EtherNet/IP
TM
protocol (
section 8.4 "Communication protocol" on page 23). The yellow "AUTOCAL" LED
lights up for the duration of the calibration process (approx. 10…15 seconds). The AA bit (
A
UTOCAL
a
ctive)
is additionally set and a voltage of approximately 0 VDC appears at the actual value output (terminals 17+18).
If an ATR-x is connected, it indicates 0…3 °C.
After the zero point has been calibrated, the "AUTOCAL" LED goes out and a voltage of 0.66 VDC (300 °C
range) or 0.4 VDC (500 °C range) appears at the actual value output. If an ATR-x is connected, it must be set
to "Z".
If the zero point was not calibrated successfully, the AL bit (
al
arm active) is set and the red "ALARM" LED blinks
"ALARM" LED
"OUTPUT" LED
ACTION
OFF
Short impulses every 1.2 s
Go to step 8
BLINKS fast (4 Hz)
OFF
Go to step 8
LIT continuously
OFF
Error diagnosis (
section 8.19)
!
!