Startup and operation
Page 16
RES-5011
Version 2
7.2.2
Configuration of the rotary coding switch for the temperature range and alloy
The setting of the rotary coding switch for the temperature range and alloy can be overwritten with
the parameter data (
section 8.7 "Parameter object (class: 0x0F)" on page 28).
If the switch is set to "9", more temperature ranges and alloys can be selected in the ROPEX visualization software
(
section 8.12 "USB interface for visualization software ROPEXvisual
7.2.3
Configuration of the rotary coding switch for the IP address
These coding switches allow you to set the least significant byte in the IP address of the RES-5011 in the EtherNet/
IP
TM
network to a value between 0x01 and 0xFD. A new setting does not take effect until the next time the con-
troller is switched on. The preset IP address of the RES-5011 is configured as follows, depending on the settings
of the rotary coding switches:
The "00" switch position allows an IP address to be assigned, or the DHCP client switched on and off, via the
EtherNet/IP
TM
interface either using a software tool (e.g. Rockwell’s "BOOT / P-DHCP Server") or by manually
accessing the TCP / IP object. These settings are stored in the controller. However, when the power supply to the
controller is momentarily interrupted, the stored values are only used if the rotary coding switches are set to "00".
All other switch positions cause the stored values to be temporarily overwritten.
Rotary coding switch
IP address
00
DHCP client active or if DHCP client was deactivated: Last IP address assigned
is static
01…FD
192.168.001.
1…253
FE
Configuration determined by PC visualization software
FF
Last configuration assigned is erased
0
5
1
2
3
4
6
7
8
9
AUX
CONF
IG
URA
TIO
N
ALARM
OU
TP
UT
ENE
RG
IZ
ED
(
)
AT
ALARM
-
DEE
NE
RG
IZ
ED
SWIT
CH
PO
S.
1
0
4
5
8
9
TE
MP.
RA
NGE
300°
C
300°
C
500°
C
500°
C
300°
C
PC
C
ONF
IGU
RA
TION
780p
pm
/K
1100
pp
m/K
(L)
(A2
0)
1100
pp
m/K
(A
20)
780
pp
m/K
350
0ppm
/K
(L)
0
5
1 2
3
4
6
7
8
9
Switch
position
0
1
4
5
8
300°C
300°C
500°C
500°C
300°C
1100ppm/K
780ppm/K
1100ppm/K
780ppm/K
3500ppm/K
e.g. Alloy-20
e.g. Alloy L
e.g. Alloy-20
e.g. Alloy L
Temp.
range
Temp.
coefficient
Band
alloy
0 = Factory settings
9
PC-CONFIGURATION
TEM
P . CO
EFF
ICIE
NT
!
0
0
F
F
E
E
D
D
C
C
B
B
A
A
9
9
8
8
7
7
6
6
5
5
44 3
3
2
2
1
1
IP address selectable.
00 = Factory settings
0
0
F
F
E
E
D
D
C
C
B
B
A
A
9
9
8
8
7
7
6
6
5
5
44 3
3
2
2
1
1
0...F
0...F
IP address static or
obtained from DHCP
IP address preset to
PC configuration
01...FD
00
FE
192.168.001.XX
“Out of the box” config.
FF