6
COMPACT 33:
NAME
VALUE
UNIT
Dimension
720 x 950 x 1475
mm
Mass
285
kg
Thank capacity
90
kg
The door of the tank
610 x 320
mm
Water capacity of the boiler
70
l
Cleaning door
260 x 200
mm
NAME
VALUE
UNIT
Installation place
4.22
m
2
The height from the floor to axis of the flue
terminal
210
mm
The height from the floor to axis of the hot water
terminal
1145
mm
The height from the floor to axis of the cold water
terminal
565
mm
The height from the floor to axis of the
(filling/emptying) terminal
565
mm
Flue terminal diameter
80
mm
Diameter of exterior air intake on the wall
60
mm
Diameter of the hot water terminal
1”
col
Diameter of the cold water terminal
1”
col
Diameter of the (filling/emptying) terminal
1/2
col
Voltage and frequency
220 /5/50
V/A/Hz
NAME
VALUE
UNIT
The power of the water heater
at (min/max) power
9.0 – 30.0
kW
Heating volume
220
m
2
Water pressure
1.5 – 2.5
bar
Water temperature
65 – 80
˚C
Flue temperature
∼
160
˚C
Optimal draft
0.05 – 0.1
mbar
The main/max consumption
2.1 – 6.2
kg/h
Volume of expansion vessel
---
---
Pump power (max)
93
W
Summary of Contents for SM ECO 25
Page 7: ...7 Figure 1 Boiler SM ECO 33 compact ...
Page 36: ...36 ...
Page 37: ...37 Figure 28 Power Fan Temperature Fuel Time Settings ...
Page 44: ...44 16 6 ELECTRICITY SCHEME Figure 30 Electricity scheme ...
Page 47: ...47 ...
Page 48: ...48 16 8 ALARMING SITUATION ...
Page 49: ...49 ...
Page 50: ...50 ...