9 Deforest Street, Amityville, New York, 11701 USA
www.romanoff.com
36
Operation of a dust vacuum and Filter System
A) Start/Stop button
B) Manual speed control
1) Filter-saturation indication
2) System status indication
3) Power setting/hour meter indication
4) Temperature and turbine error
indication
5) Filter-cleaning-active indication
6) Filter status indication
Pos. Description
A)
The system is switched on with the Run/Standby button
(The unit switch must be set to ON)
1)
The status of the filters can be easily monitored via the filter-saturation indication.
The total filter saturation of all installed filters is displayed together.
6)
The filter status indication shows quickly and easily which filter has to be changed (number of
filters depends on the system).
5)
Filter cleaning activated (actuation depends on filter cleaning, only on systems with filter
cartridge)
C)
Button for manual filter-cleaning actuation (only on systems with filter cartridge)
9.3
Operation via Interface
The system can be remote controlled.
The following functions are available:
•
Indication „Filter saturated“
•
Switch-over between Run/Standby
•
Speed control
The system can be controlled via the interface.
For details on the interface assignment, please refer to section:
“INSPIRE interface”.
The following functions are available:
•
Filter full/ Filter full, inverted
•
Run/Standby
•
Speed monitoring
•
Temperature indication
•
External speed control
•
Group error