Operating and Maintenance Manual
23 |
P a g e
D e c a p p e r O & M M a n u a l R e v D
2.
Please note the side view showing the linkage is the correct position
for the case pusher in the forward stroke position
3.
Loosen the locknut on the linkage between the case pusher and
decapper.
4.
Loosen the UPPER pivot bolt going through the bearing (Do NOT
touch the lower bolt).
5.
Screw the bearing in / out as required. Usually only 1 or 2 turns are
required. Replace the pivot bolt and tighten bolts and lock nuts.
Check the case pusher position and adjust as required.
❖
Do not touch the lower pivot bolt as over tightening may
damage the case pusher.
➢