Operating and Maintenance Manual
10 |
P a g e
D e c a p p e r O & M M a n u a l R e v D
The tube is supplied coiled in the box and will often want to stay that way.
Running (and holding) hot water in the tube for a few minutes will allow
the tube to relax and straighten out.
❖
It helps if you knead the hose whilst it is hot and hang it vertically
whilst it cools.
The decapper machine has 4 places where hold down bolts or screws can
be used. Refer to the photos in this manual.
In most installations, hold down screws will not be required, but if you
place it in a position where it can get knocked off the bench, then screw it
down to be safe.
❖
If the decapper falls off your bench onto concrete, you will break
something. We have replacement parts if required.
➢
FW Arms Decapper installation
The FW Arms Decapping Die supplied with the decapping machine is a
proprietary product that has been customized for the Rollsizer.com
decapper.
It is not a standard FW Arms decapping unit.
The installation of
the decapping unit must only be done with the decapper linkage shown in
the position shown in the photo below. This ensures the decapper body
will not touch / crush the pegs in its lowest position.
Failure to follow this procedure will break or damage the pegs or the
decapper body. This is NOT a warranty claim.
The decapper will only work with Small Pins. Using the FW Arms large
pins will result in the cases jamming on the pin and being pulled up and
out of the pegs.
Please read the Instructions supplied with the FW Arms Decapper. The
manual explains the safe pin removal / replacement procedure. The
supplied decapper parts include specialized spanners to remove broken
pins and a spare guide rod. Pins should be finger tight only with the locktite
and left to set for a minimum of 1 hour before use.