Manual No. 4801-5156 Rev 4-08
RollSeal SC-325 & SC-650
Page 29 of 44
12.5 Connecting AC Power to the Smart Controller
Inset A
Inset B
OR
Inset C
OR
Smart Controller – Right & Left Side Compartments
Inset B
Inset C
SWX2: AC Voltage
Selection Switch
J1: AC Voltage
Selection Jumper
W A R N I N G !
Dangerous High Voltages!
Allow Approximately 5 Minutes For The Controller To Power-Down
Before Changing Switch Settings, Jumper Placement, Or Wiring.
The SC-325/SC-650 controllers and RS-500/600 doors can be field
upgraded to accommodate either 115 VAC or 230 VAC power
supply. If the desired power supply voltage is different from the
factory preset/prewired voltage, the appropriate version Brake
Rectifer must be ordered separately, field-installed on the RS Door,
and the SC controller switch & jumper settings changed
accordingly.
W A R N I N G !
Only a qualified electrician should install
and/or service this equipment.
Failure to observe precautions could result in
equipment damage, severe bodily injury, or
loss of life.
The SC-325 controllers are factory preset to 115 VAC and the RS-500
doors factory prewired to require a 115 VAC power supply.
The SC-650 controllers are factory preset to 230 VAC and the RS-600
doors factory prewired to require a 230 VAC power supply.