WARNING: DO NOT Turn The Power ON Until All Of The Following Items Are Completed:
All Wire And Cable Connections Are Completed.
The Voltage Selection Switch And Jumper Are Set To Match The Required Supply Voltage.
The Motor Brake Rectifier Is Wired Accordingly To Match The Required Supply Voltage.
6.3 Switch
Settings
SWX1 contains two separate switches. The first switch (SWX1:1) controls the Safety Action and
the second switch (SWX1:2) determines the Encoder Selection as follows:
PCB 154 SWX1:1 – SAFETY ACTION
Selects the
operation of the door when the Safety Beam is interrupted during closing. If
at any time while the door is closing, the Safety Beam is interrupted, the door will stop.
Then if SWX1:1 is “On” the door will proceed to open to its full open position. If
SWX1:1 is “Off” the door will stop and await a command to either continue opening or
to close. See
Section 12.1
for the location of SWX1 on the printed circuit board.
PCB 154 SWX1:2 – ENCODER SELECTION
Selects between the use of one encoder (SWX1:2=Off) or two encoders (SWX1:2=On)
when determining the door position. Some doors will be equipped with two encoders.
See
Section 12.1
for the location of SWX1:2 on the printed circuit board.
PCB 154 SWX2 Switch and MOTOR DRIVE J1 Jumper– VOLTAGE SELECTION
The Smart Controller contains one switch and one jumper which must be set prior to
initial use and application of power. Ensure that SWX2 and J1 are both set according to
the specific required voltage. Refer to
Section 12.1 (
for V1)
or 12.3
(for V2) and
12.5
for the location of SWX2 on PCB 154 and J1 on the Motor Drive board assembly.
The SC-325 controllers are factory preset to 115 VAC and the RS-500 doors factory
prewired to require a 115 VAC power supply. The SC-650 controllers are factory preset
to 230 VAC and the RS-600 doors factory prewired to require a 230 VAC power supply.
The SC-325/SC-650 controllers and RS-500/600 doors can be field upgraded to
accommodate either 115 VAC or 230 VAC power supply. If the desired power supply
voltage is different from the factory preset/prewired voltage, the appropriate version
Brake Rectifer must be ordered separately, field-installed on the RS Door, and the SC
controller switch & jumper settings changed accordingly. Refer to
Section
12.6
for
specific RS-500/600 Motor Brake Rectifier wiring diagrams.
6.4 Door
Setup
The door limits are used to adjust the door position in the full open and closed positions. To set
the door limits, use the following steps:
(1)
Depress the
Mode
button (
●
) for at least 5 seconds. P1 (Close Time Delay) will be then
be displayed in the Display Indicator.
(2)
Depress and release the
Mode
button until PS1 (Change Program Limits) is displayed.
(3)
Depress
Up
( ) until “yes” is displayed.
(4)
Depress the
Mode
button again (
●
). PS2 (Set Open Limit) will be displayed.
(5)
The door will proceed to the open limit and then stop. Once the door stops, adjust open
limit using the
Up
( ) or
Down
( ) buttons until open limit is satisfactory.
(6)
Depress the
Mode
button (
●
) again. PS3 (Set Closed Limit) will be displayed.
(7)
The door will proceed to the closed limit and then stop. Once door stops, adjust this limit
using the
Up
( ) or
Down
( ) buttons until the close limit is satisfactory.
(8)
Depress the
Mode
button (
●
) again and the controller will exit the programming mode
and return to displaying the actual position.
(9)