Manual No. 4801-5156 Rev 4-08
RollSeal SC-325 & SC-650
Page 19 of 44
9.
Troubleshooting Controller and/or Door
9.1
P12 – Input Status Indicators
This parameter is used to service or troubleshoot the door. The various inputs are represented by
LED segments on the display as shown below.
If a display segment is “ON”, the switch is Made; Segment is “OFF”, switch is Not Made.
For Example, when the Safety Beam is obstructed, the Safety Beam display segment will turn ON
and remain ON until the obstruction is removed.
*Available on Software versions V0.21 and later.
Important Indicators:
For the door to operate, the “Safety Switch” and “Health” display segments must be “ON”.
For the door to close, the “Safety Beam” & “Leading Edge” display segments must be
“OFF”.
If the “Stop Switch” display segment is “ON”, the door will not operate.
If the “Open Switch” display segment is “ON”, the door will not close.
“Safety Response” display segment “ON” indicates that the piano switch selector is ON and
the door will Stop and Reverse upon contact with Safety Beam or Leading Edge; “OFF”
means it will Stop only.
“Encoder” display segment “ON” indicates that the door is operating off of two encoders;
“OFF” indicates one encoder.
“Health” indicates that the AC Drive is OK and that the controller is allowed to initiate door
movement.