11
Appendices
The components in the S-4000 System provide many different indicators that show the current system status.
Additionally, the units provide error indicators that let you know whenever a potentially serious problem is
detected in the system. The following tables show the meaning of the various status and error indicators, and
suggest actions for troubleshooting and safe system operation.
S-240P: External Power Supply Unit
* In the interest of product improvement, the specifications and/or appearance of this unit are subject to
change without prior notice.
Troubleshooting
Power and Alarm Indicators
Indicator
Status
Definition
Troubleshooting Action
POWER
Lit
Power is received
•
None
Dark
No power is received
•
Make sure S-240P is turned on
•
Check the power cord
Indicator
Status
Definition
Troubleshooting Action
ALARM
Lit
Abnormal (high) temperature
detected
•
Make sure the intake and/or exhaust vent s on the unit are
not blocked.
•
Shut down the unit to prevent overheating and damage
An exhaust fan (or fans) has
stopped working
•
Shut down the unit to prevent overheating and damage
Connector Information
DC OUTPUT 24V 6A
Pin
Function
+1
+24V
-1
+2
GND
-2
Specification
Connectors
INT.POWER AC INPUT
DC OUTPUT 24V 6A
Indicators
POWER Indicator
ALARM Indicator
Power Supply
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
Power Supply (for an S-4000 unit)
24 V 6A DC
Power Consumption
180 W
Dimensions
482 (W) x 340 (D) x 89 (H) mm
19 (W) x 13-7/16 (D) x 3-9/16 (H) inches
Weight
5.4 kg
11 lbs 15 oz
Operation Temperature
0 to +40 degrees centigrade
+32 to +104 degrees Fahrenheit
Accessories
Power Cord, Owner’s Manual
S-240P_e.book 11 ページ 2007年5月23日 水曜日 午後2時52分