![Roland PNC-1600 User Manual Download Page 35](http://html1.mh-extra.com/html/roland/pnc-1600/pnc-1600_user-manual_1481412035.webp)
33
Device control
Device control instructions are used to determine the communication sequence between the PNC-1900/1600 and
computer through RS-232C interface and/or tell the PNC-1900/1600 the current computer state. among them, some
device control instructions set the output specifications of mode 2 instructions.
Each device control instruction is organized with three letters: ESC (1Bh), “.” and one uppercase letter. Device
control instructions are of two types: one with parameters and the other without parameters.
Parameters can be omitted. A semicolon “;” is used as a delimiter to separate parameters if they are input in
succession. A “;” without parameters means that parameters were omitted.
If parameters are omitted, the default value is set. For a device control instruction with parameters, a terminator
needs to be input in order to signify the end of instructions. A colon “:” is used as the terminator which cannot be
Signal
Name
Terminal
Number
Signal
Name
Pin Connection
NC
36
18
HIGH***
HIGH*
35
17
GND
NC
34
16
GND
GND
33
15
NC
HIGH*
32
14
NC
NC
31
13
HIGH**
GND
30
12
GND
29
11
BUSY
28
10
ACK
27
9
D7
26
8
D6
25
7
D5
24
6
D4
23
5
D3
22
4
D2
21
3
D1
20
2
D0
19
1
STROBE
36
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
19
18
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
+5V
+5V
+5V
100
Ω
1.2 K
Ω
3.3 K
Ω
**
=
*
=
***
=
4.2 The Specifications of the Interfaces
Serial Interface (RS-232C)
●
Connector
Instruction
Format
Parameter
Range ([ ] is default)
Explanation
Handshake Instructions
ESC .B
[ESC].B
None
Outputs the current remaining buffer capacity.
Output Remaining
Buffer Capacity
ESC .M
[ESC].M<P1>;<P2>;
P1:Delay time
0—32767(msec) [0(msec)]
Sets handshake output specifications.
Set Handshake
<P3>;<P4>;<P5>;<P6>:
P2:Output trigger character
[0(Sets nothing)]
Output
P3:Echo terminator
[0(Sets nothing)]
Specifications (1)
P4:Output terminator
[13([CR])]
Note:When you specify some values to <P4> and
P5:Output terminator
[0]
<P5>, always set 0 to <P6>. When you specify
P6:Output initiator
[0(Sets nothing)]
some value to <P6>, always set 0 to <P5>.
ESC .N
[ESC].N<P1>;<P2>;
P1:Intercharacter delay
0—32767(msec) [0(msec)]
Sets an intercharacter delay, and also an Xoff chara-
Set Handshake
<P3>;・・・・・;<P11>:
P2—P11
[All 0(Sets nothing)]
cter for performing the Xon/Xoff handshake.
Output
:Xoff character (for Xon/Xoff)
Specifications (2)
Immediate response character
(for ENQ/ACK)
Parallel Interface (in compliance with
specifications of Centronics)
●
Connector
25
.
.
.
.
.
.
.
.
.
.
14
13
.
.
.
.
.
.
.
.
.
.
.
1
Signal
Name
Terminal
Number
Signal
Name
Pin Connection
NC
25
13
NC
NC
24
12
NC
NC
23
11
NC
NC
22
10
NC
NC
21
9
NC
DTR
20
8
NC
NC
19
7
SG
NC
18
6
DSR
NC
17
5
CTS
S.RXD
16
4
RTS
NC
15
3
RXD
S.TXD
14
2
TXD
1
FG