123
Error Message List
If an incorrect operation is performed, or if processing could not be performed as you specified, an error message appears .
Refer to the explanation for the error message that appears, and take the appropriate action .
Message
Meaning
Action
USB Memory Not
Ready!
The USB flash drive is not inserted, or is inserted incompletely .
Turn off the power, insert the USB flash drive correctly, and then turn the
power on again (p . 20) .
The USB flash drive was removed after you selected data that was on
the USB flash drive .
The format of the USB flash drive is invalid .
Use the FANTOM to format the USB flash drive (p . 109) .
Storage Full!
There is insufficient space in the writing-destination .
Delete unneeded data .
Incorrect File!
The format of the file being imported is invalid or unsupported .
Use a file format that the FANTOM supports .
Audio files (WAV/AIFF/MP3) are supported (p . 68) .
Not Found! Empty
PAD was not found.
During AUTO IMPORT of samples, there were not enough empty pads
for the samples being imported .
Use the sample DELETE function (p . 72) to prepare a sufficient number of
empty pads, and then try the operation again .
Sample Too Long!
The allowable sampling time has been exceeded .
–
Sample Length Too
Short!
The sample is too short, and cannot be edited correctly .
If the sample is extremely short, editing may not produce the desired result .
Storage Protected!
Since the USB flash drive’s lock setting is on, writing or deletion is not
possible .
Turn off the power, disconnect the USB flash drive, and turn off its lock setting .
Storage Error!
There is a problem with the storage that is the target of the operation .
If the target storage is in
5
A USB flash drive: Use the FANTOM to format the USB flash drive (p . 109) .
5
INTERNAL STORAGE: Execute the INITIALIZE INTERNAL STORAGE operation
5
Sample memory: Execute the sample DELETE ALL operation (p . 72) .
In other cases, execute a factory reset (p . 109) .
If this does not solve the problem, contact your dealer or customer support .
Incorrect Path!
When using File Utility, the Copy/Move destination path is invalid .
A subfolder that includes the Copy/Move source cannot be specified as the
Copy/Move destination .
Invalid File/Folder
Name!
The file or folder name includes characters that cannot be handled by
the FANTOM .
The FANTOM cannot handle files or folders whose name includes the
following characters .
Nor can it handle special characters such as double-byte characters .
Do not use these characters .
Invalid Char!
Unusable characters are included .
Characters that cannot be handled by the FANTOM are shown in the error
message .
Do not use these characters .
Pattern End!
You have exceeded the maximum measures that can be realtime-
recorded .
–
Sequencer Error!
A sequencer-related error has occurred .
Turn the power off and then on again before you proceed (p . 20) .
Data Full!
Since the maximum number of notes that can be stored in a pattern
has been exceeded, no further recording or editing is possible .
Use the pattern utility modify commands Delete or Erase to delete unneeded
data from the pattern that you’re recording or editing (p . 91) .
Pattern status is
different!
When recording a layer consisting of multiple zones, the recording-
destination includes multiple tracks of differing pattern status .
If you are layer-recording tracks, make sure that the loop settings (loop length,
playback position, LOOP SW setting) for the patterns of those tracks are
consistent with each other (p . 82) . .
Now Recording!
Since the FANTOM is recording, this operation cannot be executed .
Stop recording before you execute the operation .
Now Playing!
Since the FANTOM is playing, this operation cannot be executed .
Stop playback before you execute the operation .
Program Version Error!
The FANTOM cannot start up .
The program cannot be loaded correctly . Alternatively, the system
update program might be incorrect .
Using the correct program, perform the update once again .
If this does not solve the problem, contact your dealer or customer support .
MIDI Buffer Full!
An unusually large amount of MIDI data was received, and could not
be processed .
Reduce the amount of MIDI messages that are being transmitted .
MIDI Offline!
The MIDI IN connection was broken .
Check that there is no problem with the MIDI cable connected to the
FANTOM’s MIDI IN, and that the MIDI cable was not disconnected .