background image

ROLA-CHEM Digital Controller                                        PN 554135      5/04/2017                                                   Page: 2 of 20 

1.  SAFETY

:  When installing and using this electrical equipment, basic safety precautions 

should always be followed, including: 

 

1.1  WARNING!

  To reduce the risk of injury, do not permit children to use this product unless they 

are closely supervised at all times 

 
1.2  WARNING!

 Risk of electric shock. 

   

          

Connect only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI). 
Contact qualified electrician if you cannot verify that the receptacle is protected by a GFCI and that 
your installation meets local electrical codes, including grounding of water system components.  
 

1.3  WARNING!

 Risk of electric shock. 

Do not bury electric cords. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and 
other equipment.  Replace damaged cords immediately.  Do not use extension cords.   

 
1.4  WARNING!

 Risk of electric shock. 

Install at least 10 feet (3.0m) from inside wall of water enclosure using non-metallic plumbing.   
Do not install this controller in a location accessible to the public. 
 

1.5  WARNING!

 Risk of Chemical Overdose/Exposure.  

Removing power from circulating pump must also remove power from the controller. 
Provide a properly located outlet controlled by the circulating pump circuit. 
 

1.6  WARNING!

 Risk of electric shock/pinching/chemical exposure. 

Remove power sources or lockout circuit prior to performing maintenance on controller. 

 

 

1.7  WARNING!

 Risk of Chemical Overdose/Exposure.  

Use a device such as a flow switch to shut off power from the controller in the event of circulating 
pump failure.  It is unsafe to automatically dispense chemicals into a circulating system that is not 
running.  

 
1.8  WARNING!

 Risk of Chemical Exposure. 

Pool water must be balanced and stabilized before operating this controller.

 

 

1.9  WARNING!

 Risk of Chemical Overdose/Exposure.  

Minimize amount of chemical on site that is available to dispense.  
Size the feeder and container to pool/spa capacity. 
Dilute chemical for small bodies of water. 
 

1.10 WARNING!

 Risk of Chemical Exposure.  

Do not shut down circulation and control system immediately after using pool, spa or hot tub.  
Systems must operate until water chemistry is stable. Systems must be restarted before water 
chemistry is out of NSPI recommended ranges or water chemistry must be manually corrected. 
 

1.11 WARNING!

 Controller uses microprocessor.  

Wireless communication equipment or other electrical devices operated in close proximity may 
cause inadvertent actuation of chemical feed pumps. 

Summary of Contents for RC554000

Page 1: ...F MODE FEED ONCE pH AUTO ORP LEVEL SET pH FEED ALERT CALIB pH FEED TIME HI ORP LOW ORP FEED L O W ALERT pH Operating Manual MODELS RC554XP AND 554000 ORP pH Digital Controller IMPORTANT SAFETY INSTRUC...

Page 2: ...lso remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 6 WARNING Risk of electric shock pinching chemical exposure Remove power sources or...

Page 3: ...ols 7 4 Installation 4 1 Locating the controller 10 4 2 Mechanical installation 10 4 3 Power panel access 11 4 3 1 Dip switches 11 4 3 2 Fuses 11 4 3 3 Flow switch 11 5 Operation 5 1 Startup 12 5 2 pH...

Page 4: ...low pH 8 0 high 7 0 low To Change Settings Press and release the MODE button until the desired ORP or pH LED is lit Once the settings are changed they will remain at those settings until they are chan...

Page 5: ...ontinuously during the feed delay portion of the feed cycle The ORP Alert lamp will illuminate when the ORP reading is higher or lower than the high and low ORP Alert set points and prevent the feedin...

Page 6: ...ire grounded power cord Combined load not to exceed 10 amps GFCI source required Output Power 120 Volts AC 50 60 HZ 5 amps fused for both ORP and pH Two 3 wire grounded power receptacles Terminal stri...

Page 7: ...ing feed delay 4 pH ORP DIGITAL DISPLAYS Monitors pH and ORP and displays programmed set points 5 pH STANDBY LAMP AND PROGRAMMING BUTTONS When pH standby lamp is illuminated the six set buttons are en...

Page 8: ...ssing the FEED ONCE button the pH feeder will feed and delay for one complete feed cycle See FEED TIME Button for feed delay times If the Feed time is set for Continuous feed the manual feed will not...

Page 9: ...ET LEVEL button which displays in 5 mV increments until the desired level is reached Feed Time The feed times are displayed in seconds There is a five 5 minute delay time associated with each feed tim...

Page 10: ...roller in a location accessible to the public Install the controller in an area protected from natural elements sun rain freezing etc See appendix for typical feed system schematics 4 2 Mechanical Ins...

Page 11: ...dix for settings 4 3 2 Fuses The ORP and pH are independently fused to protect the controller from defective feeders These fuses are located inside the lower panel The fuse holders are shipped with 5...

Page 12: ...n the OFF mode turn the filter pump on and check for leaks in the system and flow through the flow cell The flow lamp will be illuminated if the controller has power it is connected to the flow switch...

Page 13: ...until the AUTO LED is lighted This is the operational mode for the controller The controller must be in this mode for the feeders to maintain the desired parameters Note When using the RC554XP or 5540...

Page 14: ...affected by pH probe Both probes must be in good operating condition 6 3 Set points not being reached maintained Factory setting for feed time is 0 6 sec on with 5 minute delay Feeders may require lo...

Page 15: ...and return to operating mode The last two steps are extremely important because this puts the controller back in operating mode If these two steps are not performed the controller will remain in test...

Page 16: ...are not covered under this warranty Heavy duty probes are warranted from the date of original purchase for one 1 year ROLA CHEM under no circumstances shall be liable for any consequential damages di...

Page 17: ...eed Alert Limit feature in the timed feed mode 1 Turn off remove power then move 2 dip switch to ON 2 Re power press MODE to set it for ORP or pH 3 Set FEED TIME to OFF 4 Press FEED ONCE to select the...

Page 18: ...mode shortens minutes to seconds E Turn the controller Off again to exit test mode F Turn the controller On to return to operating mode The last two steps are extremely important because this puts th...

Page 19: ...CLEAR OF DEBRIS FLOWSWITCH EARTH GROUND WATER TO POOL ACID PUMP HEATER ACID HCl MANIFOLD FLOWSWITCH VALVE EARTH GROUND WATER FROM POOL WATER TO POOL EARTH GROUND SYSTEM USING EROSION FEEDER TRI CHLOR...

Page 20: ...FROM POOL BASKET POOL PUMP FILTER CONTROLLER FLOWSWITCH CELL WATER TO POOL SPDT 120 VAC COIL RELAY COM NO NC MANIFOLD FLOWSWITCH STRAINER VALVE SAFETY FLOWSWITCH TO ENSURE CIRCULATION TO CONTROL PROB...

Reviews: