ROLA-CHEM Digital Controller                                        PN 554135      5/04/2017                                                   Page: 8 of 20 

Modes:  

The controller has four modes of operation: 

   ON/OFF  mode. 

  AUTO mode – normal operation mode 

  pH - setting mode 

  ORP - setting mode 

To move from one mode to another simply press the MODE button.  
The illuminated lamp indicates the current mode. 
 

3.3.1 On/off mode:   

 

To turn the controller “ON”: press the MODE button.  

 

To turn the controller “OFF”: press and change MODE to pH or ORP and hold the MODE 

button for two seconds until both displays read “OFF”.  Release the MODE button and the 
controller turns off and the displays go blank.   
Note: Turning the controller “OFF” using the MODE button simply turns off the controller 
functions, but does not turn off the power to the controller. The ‘FLOW’ lamp located at the center 
of the controller is both the power light and a flow indicator when an optional flow switch is used. 
 

3.3.2 AUTO mode:

 This is normal operation mode. The controller operates the respective feeders 

to automatically maintain the parameters set for both pH and ORP. 
 

3.3.3 pH SET mode:

 This enables the six programming buttons to set desired pH parameters.  

 
Note: When scrolling through the set modes, to reverse the direction simply release the button 
momentarily and press the button again. 
 

Feed Once button

:  By pressing the FEED ONCE button, the pH feeder will feed and delay for 

one complete feed cycle.  See FEED TIME Button for feed/delay times. If the Feed time is set 
for “Continuous feed” the manual feed will not operate. 

 

Set Level button

:  Pressing the SET LEVEL button once will display the current set level. To 

change the set level, press and hold the SET LEVEL button (which displays in 0.1 pH 
increments) until the desired level is reached. 

 

Feed Time

: The feed times are displayed in seconds.  

    Each feed cycle includes a five (5) minute delay time. Pressing the FEED TIME button allows 

the user to scroll through the available feed times. Release the button when the desired pH 
feed time is reached.  To set the controller in Continuous feed, release the button when the 
display reads “con”. Continuous feed runs feeder continuously until set point is reached and 
the current feed cycle is complete or until Consecutive Feed Alert Limit is reached or until 
Hi/Low Alert limit is reached. See appendix for Consecutive Feed Alert Limit details. Feed time 
can also be set to “off”. 

 
Note: The controller will overshoot the pH setpoint by 0.1 to reduce on/off cycles. 

 

Hi Alert

:  Pressing the HI ALERT button allows the operator to set or turn off the HI alert level 

feature. As the button is pressed the pH readout will scroll through the available HI alert pH 
levels (7.5 to 8.4 and off). Release the button when the desired level is reached. The Hi Alert 
cannot be turned off in the BASE feed selection. 

Summary of Contents for RC554000

Page 1: ...F MODE FEED ONCE pH AUTO ORP LEVEL SET pH FEED ALERT CALIB pH FEED TIME HI ORP LOW ORP FEED L O W ALERT pH Operating Manual MODELS RC554XP AND 554000 ORP pH Digital Controller IMPORTANT SAFETY INSTRUC...

Page 2: ...lso remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 6 WARNING Risk of electric shock pinching chemical exposure Remove power sources or...

Page 3: ...ols 7 4 Installation 4 1 Locating the controller 10 4 2 Mechanical installation 10 4 3 Power panel access 11 4 3 1 Dip switches 11 4 3 2 Fuses 11 4 3 3 Flow switch 11 5 Operation 5 1 Startup 12 5 2 pH...

Page 4: ...low pH 8 0 high 7 0 low To Change Settings Press and release the MODE button until the desired ORP or pH LED is lit Once the settings are changed they will remain at those settings until they are chan...

Page 5: ...ontinuously during the feed delay portion of the feed cycle The ORP Alert lamp will illuminate when the ORP reading is higher or lower than the high and low ORP Alert set points and prevent the feedin...

Page 6: ...ire grounded power cord Combined load not to exceed 10 amps GFCI source required Output Power 120 Volts AC 50 60 HZ 5 amps fused for both ORP and pH Two 3 wire grounded power receptacles Terminal stri...

Page 7: ...ing feed delay 4 pH ORP DIGITAL DISPLAYS Monitors pH and ORP and displays programmed set points 5 pH STANDBY LAMP AND PROGRAMMING BUTTONS When pH standby lamp is illuminated the six set buttons are en...

Page 8: ...ssing the FEED ONCE button the pH feeder will feed and delay for one complete feed cycle See FEED TIME Button for feed delay times If the Feed time is set for Continuous feed the manual feed will not...

Page 9: ...ET LEVEL button which displays in 5 mV increments until the desired level is reached Feed Time The feed times are displayed in seconds There is a five 5 minute delay time associated with each feed tim...

Page 10: ...roller in a location accessible to the public Install the controller in an area protected from natural elements sun rain freezing etc See appendix for typical feed system schematics 4 2 Mechanical Ins...

Page 11: ...dix for settings 4 3 2 Fuses The ORP and pH are independently fused to protect the controller from defective feeders These fuses are located inside the lower panel The fuse holders are shipped with 5...

Page 12: ...n the OFF mode turn the filter pump on and check for leaks in the system and flow through the flow cell The flow lamp will be illuminated if the controller has power it is connected to the flow switch...

Page 13: ...until the AUTO LED is lighted This is the operational mode for the controller The controller must be in this mode for the feeders to maintain the desired parameters Note When using the RC554XP or 5540...

Page 14: ...affected by pH probe Both probes must be in good operating condition 6 3 Set points not being reached maintained Factory setting for feed time is 0 6 sec on with 5 minute delay Feeders may require lo...

Page 15: ...and return to operating mode The last two steps are extremely important because this puts the controller back in operating mode If these two steps are not performed the controller will remain in test...

Page 16: ...are not covered under this warranty Heavy duty probes are warranted from the date of original purchase for one 1 year ROLA CHEM under no circumstances shall be liable for any consequential damages di...

Page 17: ...eed Alert Limit feature in the timed feed mode 1 Turn off remove power then move 2 dip switch to ON 2 Re power press MODE to set it for ORP or pH 3 Set FEED TIME to OFF 4 Press FEED ONCE to select the...

Page 18: ...mode shortens minutes to seconds E Turn the controller Off again to exit test mode F Turn the controller On to return to operating mode The last two steps are extremely important because this puts th...

Page 19: ...CLEAR OF DEBRIS FLOWSWITCH EARTH GROUND WATER TO POOL ACID PUMP HEATER ACID HCl MANIFOLD FLOWSWITCH VALVE EARTH GROUND WATER FROM POOL WATER TO POOL EARTH GROUND SYSTEM USING EROSION FEEDER TRI CHLOR...