2.1.5
Power Supply Fault (R&S VU813)
The instrument has three power supply units. The instrument controller is supplied with
power from an auxiliary power supply unit with current-limited output. All lines carrying AC
supply voltage and high current are covered to prevent touching (double insulation,
sheathed coshrink-on sleeve).
If primary side components fail, the primary fuse trips. Transfer of primary side overcurrent
to the secondary side is prevented by the potential isolation of the power supplies. The sup-
ply of power to the instrument controller is safeguarded by means of the output-current lim-
itation of the auxiliary power supply unit.
In view of the power required from the current supply, the current available at the auxiliary
power supply output can be as high as 10 A and as high as 70 A at the output from the am-
plifier power supplies.
2.1.6
Damage on RF Output Side
Fault
Protection mechanism
Function
Damage between AC supply
input and power supply unit
Protected by primary fuse
Primary fuse trips.
Damage to power supply
unit
Protected by primary fuse
Primary fuse trips.
Damage between amplifier
power supplies and amplifier
board
Current limited by amplifier power sup-
plies
Current limited
Overload caused by instru-
ment controller
Current limited by auxiliary power sup-
ply unit
Current limited
Fault
Protection mechanism
Function
VSWR > 1.5
Measurement of forward/reflected
power at transmitter output, calculation
of VSWR in control unit, reduction of
nominal value not sufficient.
Transmitter shutdown
after sampling 3 times
Short-circuit at antenna
Measurement of forward/reflected
power at transmitter output, calculation
of VSWR in control unit
Transmitter shutdown
after sampling 3 times
Open circuit at antenna
Measurement of forward/reflected
power at transmitter output, calculation
of VSWR in control unit
Transmitter shutdown
after sampling 3 times
Antenna detachment
Measurement of forward/reflected
power at transmitter output, calculation
of VSWR in control unit
Transmitter shutdown
after sampling 3 times
Summary of Contents for SR8000 Series
Page 3: ......
Page 7: ...5300 9677 72 0 4 EN 4 ...
Page 8: ...Broadcasting Division 5300 9677 72 1 1 EN 4 Printed in Germany CHAPTER 1 SAFETY ...
Page 9: ......
Page 21: ...5300 9677 72 1 14 EN 4 Chapter1 Safety ...
Page 22: ...Broadcasting Division 5300 9677 72 2 1 EN 4 Printed in Germany CHAPTER 2 DESIGN AND FUNCTION ...
Page 23: ......
Page 27: ...Chapter2 Design and Function 5300 9677 72 2 6 EN 4 Fig 4 R S SR8000 block diagram ...
Page 49: ...Chapter2 Design and Function 5300 9677 72 2 28 EN 4 ...
Page 50: ...Broadcasting Division 5300 9677 72 3 1 EN 4 Printed in Germany CHAPTER 3 INSTALLATION ...
Page 51: ......
Page 63: ......
Page 88: ...Broadcasting Division 5300 9677 71 5 1 EN 4 Printed in Germany CHAPTER 5 OPERATION ...
Page 89: ......
Page 157: ...Chapter5 Operation 5300 9677 71 5 70 EN 4 ...
Page 158: ...Broadcasting Division 5300 9677 72 6 1 EN 4 Printed in Germany CHAPTER 6 MAINTENANCE ...
Page 159: ......
Page 166: ...Broadcasting Division 5300 9677 72 7 1 EN 4 Printed in Germany CHAPTER 7 TROUBLESHOOTING ...
Page 167: ......
Page 168: ...Chapter7 Troubleshooting 5300 9677 72 7 3 EN 4 CONTENTS 1 Information 4 ...
Page 170: ...Broadcasting Division 5300 9677 72 8 1 EN 4 Printed in Germany CHAPTER 8 SERVICE ...
Page 171: ......
Page 184: ...Broadcasting Division 5300 9677 72 9 1 EN 4 Printed in Germany CHAPTER 9 APPENDIX ...
Page 185: ......
Page 197: ...Chapter9 Appendix 5300 9677 72 9 14 EN 4 ...
Page 198: ...Broadcasting Division 5300 9677 72 A 1 EN 4 Printed in Germany WIRING DIAGRAMS ...
Page 199: ......