Chapter 1
Safety
4
Special Hazard Information
4.1
Hazards from AC Supply Voltage
All V
rms
> 30 V AC or V > 60 V DC voltages must be regarded as hazardous. When working
on voltages constituting a shock hazard, appropriate steps must be taken to exclude all
forms of risk. Working on live components is strictly forbidden. Work on live components is
only permitted in exceptional circumstances and in full compliance with special safety pre-
cautions.
4.1.1
AC Supply
Ensure that the AC supply specifications for the system or instruments match the spec-
ifications of the local AC supply before connecting the equipment. The supply circuit
must always be protected by a fuse in order to give protection against overload and short
circuit.
Note
Obtain the specifications from this documentation and also adhere to the breaking capacity
limits of the fuses and automatic cutouts in the transmitter.
4.1.2
Replacing Fuses
Fuses in parts of instruments that can be accessed by users must only be changed
when disconnected from the power supply. As a matter of principle, replacement fuses
must comply with the specifications on the instrument labeling.
Motor protection switches and automatic line fuses in those parts of a transmitter system
that can be accessed by users must be tripped. If their response range is adjustable, the
ex-factory setting must not be altered. If settings are changed inadvertently, the correct
values shown in this documentation must be set.
4.1.3
Emergency-Off System
Transmitter racks may also be fitted with emergency-off buttons at the customer's re-
quest. These are disabled when the transmitter is delivered. It is the responsibility of the
operator to ensure that the operation of the emergency button complies with safety re-
quirements and that it is included in the emergency shutdown system of the facility. Any
emergency buttons that are not used as previously planned for emergency shutdown
purposes must be removed completely.
Setting up a transmitter in which the emergency-off devices are disabled is not permit-
ted.
The operator is responsible for ensuring that all these circuits are properly integrated
into the emergency-off system on-site. Any circuit that is not included in this scheme
must be labeled accordingly.
Summary of Contents for SR8000 Series
Page 3: ......
Page 7: ...5300 9677 72 0 4 EN 4 ...
Page 8: ...Broadcasting Division 5300 9677 72 1 1 EN 4 Printed in Germany CHAPTER 1 SAFETY ...
Page 9: ......
Page 21: ...5300 9677 72 1 14 EN 4 Chapter1 Safety ...
Page 22: ...Broadcasting Division 5300 9677 72 2 1 EN 4 Printed in Germany CHAPTER 2 DESIGN AND FUNCTION ...
Page 23: ......
Page 27: ...Chapter2 Design and Function 5300 9677 72 2 6 EN 4 Fig 4 R S SR8000 block diagram ...
Page 49: ...Chapter2 Design and Function 5300 9677 72 2 28 EN 4 ...
Page 50: ...Broadcasting Division 5300 9677 72 3 1 EN 4 Printed in Germany CHAPTER 3 INSTALLATION ...
Page 51: ......
Page 63: ......
Page 88: ...Broadcasting Division 5300 9677 71 5 1 EN 4 Printed in Germany CHAPTER 5 OPERATION ...
Page 89: ......
Page 157: ...Chapter5 Operation 5300 9677 71 5 70 EN 4 ...
Page 158: ...Broadcasting Division 5300 9677 72 6 1 EN 4 Printed in Germany CHAPTER 6 MAINTENANCE ...
Page 159: ......
Page 166: ...Broadcasting Division 5300 9677 72 7 1 EN 4 Printed in Germany CHAPTER 7 TROUBLESHOOTING ...
Page 167: ......
Page 168: ...Chapter7 Troubleshooting 5300 9677 72 7 3 EN 4 CONTENTS 1 Information 4 ...
Page 170: ...Broadcasting Division 5300 9677 72 8 1 EN 4 Printed in Germany CHAPTER 8 SERVICE ...
Page 171: ......
Page 184: ...Broadcasting Division 5300 9677 72 9 1 EN 4 Printed in Germany CHAPTER 9 APPENDIX ...
Page 185: ......
Page 197: ...Chapter9 Appendix 5300 9677 72 9 14 EN 4 ...
Page 198: ...Broadcasting Division 5300 9677 72 A 1 EN 4 Printed in Germany WIRING DIAGRAMS ...
Page 199: ......