Probe RT-ZS10L     

Safety Information RT-ZS10L

To  avoid  personal  injury  and  to  prevent  fire  or 
damage to this product or products connected 
to it, review and comply with the following safety 
precautions. Be aware that if you use this probe 
assembly in a manner not specified the protection 
this product provides may be impaired.

–  Only qualified personnel should use this probe 

assembly.

–  Use only grounded instruments.

–  Do  not  connect  the  probe  ground  lead  to  a 

potential other than earth ground. Always make 
sure the probe and the measurement instrument 
are grounded properly.

–  Connect and disconnect properly.

–  Connect the probe output to the measurement 

instrument and connect the ground lead to earth 
ground before connecting the probe to the cir

-

cuit under test. Disconnect the probe input and 
the  probe  ground  lead  from  the  circuit  under 
test  before  disconnecting  the  probe  from  the 

measurement instrument. 

–  Do not apply any electrical potential to the probe 

input which exceeds the maximum ratings of the 
probe. 

–  Make sure to comply with the voltage versus 

frequency derating curve.

–  Keep away from live circuits.

–  Avoid open circuitry. Do not touch connections 

or components when power is present.

–  Do not operate with suspected failures.

–  Refer to qualified service personnel.

–  Indoor use only.

–  Do not operate in wet/damp environment. Keep 

product surfaces dry and clean.

–  Do  not  operate  the  product  in  an  explosive 

atmosphere.

Safety symbols

The following symbols may appear on the product 
or in this manual:

Caution, risk of danger
Refer to manual

Caution, risk of electric schock

Earth (ground) terminal

Summary of Contents for RT-ZS10L

Page 1: ...R S RT ZS10L Active Probe Benutzerhandbuch User Manual Test Measurement Benutzerhandbuch User Manual Version 01 3594646002 1333081502 ...

Page 2: ...derstand 1 MΩ 1 Eingangs Kapazität 0 9 pF typisch Eingangskopplung des Messinstrumentes 50Ω AC DC Überschwingen 6 typisch Eingangs Impedanz Beachten Sie dass sich die max bemes sene Eingangsimpedanz des Tastkopfes verringert wenn sich die Frequenz des angelegten Signals erhöht Eingangsimpedanz Frequenz Hz 10k 100k 1M 10M 100 1k 10k 100k 1M 10M 100M 1G Z Ohm Frequency Hz Typical input impedance I Z...

Page 3: ...hen Ein gangskapazität belasten die Signalquelle bereits deutlich bei Frequenzen oberhalb von 100 kHz Daher ist der RT ZS10L Aktiv Tastkopf mit seinem hohen Eingangswiderstand und seiner niedrigen Eingangskapazität der ideale Tastkopf für Ihre täglichen Messaufgaben Der RT ZS10L kontaktiert benachbarte Pins von Stiftleisten im 2 54 mm Raster Lieferumfang Die folgenden Artikel sind im Lieferumfang ...

Page 4: ...des Tastkopfes vom Messpunkt bevor Sie den Tastkopf vom Messgerät trennen Legen Sie an den Tastkopf kein Potential an das die maximalen Bemessungsdaten des Tastkopfes übersteigt Stellen Sie sicher dass Sie die Spannungsminderungskurve unbe dingt einhalten Halten Sie sich fern von gefährlichen Strom kreisen Vermeiden Sie das Arbeiten an offenen und ungeschützten Stromkreisen Halten Sie sich fern vo...

Page 5: ...erät durchläuft vor dem Verlassen der Produktion einen 10 stündigen Burn in Test Anschließend erfolgt ein umfang reicher Funktions und Qualitätstest bei dem alle Betriebsarten und die Einhaltung der technischen Daten geprüft werden Die Prüfung erfolgt mit Prüfmitteln die auf nationale Normale rückführ bar kalibriert sind Es gelten die gesetzlichen Gewährleistungsbestimmungen des Landes in dem das ...

Page 6: ...istics Input resistance System 1 MΩ Input capacitance System 0 9 pF typical Oscilloscope Input Coupling 50Ω AC DC Overshoot 6 typical Probe HZO30 Input Impedance Notethattheinputimpedanceoftheprobe decreases as the frequency of the applied signal increases 10k 100k 1M 10M 100 1k 10k 100k 1M 10M 100M 1G Z Ohm Frequency Hz Typical input impedance I Z I Ohm Mechanical characteristics Weight probe onl...

Page 7: ...tive high input capacitance load the signal source already at frequencies above 100 kHz That s why the RT ZS10Lactiveprobe with its high in put resistance and its low input capacitance is the ideal probe for most of your daily measurements The RT ZS10L testing adjacent pins in 2 54 mm Pitch Included in delivery The following items are included in the scope of delivery Please check the delivery for...

Page 8: ...round lead to earth ground before connecting the probe to the cir cuit under test Disconnect the probe input and the probe ground lead from the circuit under test before disconnecting the probe from the measurement instrument Do not apply any electrical potential to the probe input which exceeds the maximum ratings of the probe Make sure to comply with the voltage versus frequency derating curve K...

Page 9: ...ensive functional quality testing to examine all operating modes and to guarantee compliance with the specified technical data The testing is performed with testing equipment that is calibrated to national standards The statutory warranty provisions shall be governed by the laws of the country in which the product was purchased In case of any complaints please contact your supplier Any adjustments...

Page 10: ... 0 8 mm Buchsen Y Leitung 890 500 800 L In Adapter 890 800 000 5 feste Spitzen Set 890 800 001 5 Federspitzen Set 890 400 800 Z Ground 018 291 103 Ground Blade P25 2 schwarz Pico hook 2 1 1 1 1 2 selbstklebende CU Masseplättchen 2 x 2 cm 2 adhesive CU Pads 2 x 2 cm Z Ground Z Ground Ground Blade Ground Blade 1 Federspitze 1 Spring Tip 1 feste Spitze 1 Solid Tip L In Adapter L In Adapter Y Leitung ...

Page 11: ... 890 020 916 Kabelmarkierer 4 Farben 890 400 804 10 cm Masseleitung 90 890 400 803 5 cm Masseleitung 90 890 400 802 Masseleitung 12 cm 890 400 802 Masseleitung 6 cm 890 020 916 Kabelmarkierer 4 Farben Kabelmarkierer 4 Farben Marker Bands 4 Colors Masseleitung 6 cm Ground Lead 6 cm Masseleitung 12 cm Ground Lead 12 cm Masseleitung 90 5 cm Ground Lead 90 5 cm Masseleitung 90 10 cm Ground Lead 90 10 ...

Page 12: ...ustomersupport rohde schwarz com Service www service rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners Throughout this manual products from Rohde Schwarz are indicated without the R S symbol e g R S RT ZS10L is indicated as RT ZS10L 1333 0815 02 Version 01 RT ZS10L ...

Reviews: