![Rohde & Schwarz FE50DTR Manual Download Page 37](http://html.mh-extra.com/html/rohde-and-schwarz/fe50dtr/fe50dtr_manual_1477823037.webp)
Operating the instrument
R&S
®
FE50DTR
37
Manual 1179.3180.02 ─ 02
Table 6-3: Simultaneous mode R&S
FE50DTR signal and connections
Signal
Vector signal generator
e.g., R&S
SMW
R&S
FE50DTR Vector signal analyzer
e.g, R&S
FSV/A
Reference
Connector: "REF Out"
Freq.: 1
GHz, 10
MHz
"Ref. In"
Connector "REF Output"
Freq.: 640
MHz, 10
MHz
LAN (Control)
"LAN"
"LAN"
"LAN"
IF In
"RF A"/"RF B"
"IF In B"
-
IF Out
-
"IF Out A"
"RF Input 50
Ω
"
RF In
-
"RF A"
-
RF Out
-
"RF B"
-
How to:
●
Chapter 4.7, "Connecting to LAN"
●
Chapter 4.8, "Connecting to SMA and 1.85
To control the R&S
FE50DTR
Either the R&S
SMW or R&S
FSV/A controls the R&S
FE50DTR exclusively
using a secure socket layer (SSL) control connection via LAN. For correct opera-
tion, the R&S
FE50DTR operates in Tx mode first and requires control by the
R&S
SMW. For analysis, the R&S
FE50DTR also operates in Rx mode and
requires control by the R&S
FSV/A.
1. At the R&S
SMW, establish the control connection to the R&S
FE50DTR.
How to:
FE50DTR with a vector signal generator"
2. At the R&S
SMW, set "Connection Mode" > "Simultaneous RX/TX".
In this state, the connection is locked by the R&S
SMW when you change
frontend settings. For example, when changing the carrier frequency at the
R&S
SMW.
After applying these changes at the R&S
FE50DTR, the R&S
SMW releases
the lock of the R&S
FE50DTR for control by the R&S
FSV/A.
3. At the R&S
FSV/A, establish the control connection to the R&S
FE50DTR.
How to:
FE50DTR with a vector signal analyzer"
on page 28
In this state, the connection is locked by the R&S
FSV/A permanently.
4. If you want to change frontend settings at the R&S
SMW, disable the control
connection between R&S
FSV/A and R&S
FE50DTR.
Operating the R&S
FE50DTR in simultaneous mode