The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliability>
See
<2_OutOfTol>
Out of tolerance result, i.e. percentage of measurement intervals
in the statistics cycle (
.
Range:
0 % to 100 %
Default unit: %
<3_CarrierPower>
RF carrier power
Range:
-130 dBm to +55 dBm
Default unit: dBm
<4_CarrierFreqErr>
Carrier frequency error
Range:
-96 kHz to +96 kHz
Default unit: Hz
<5_MultDevPosNeg> Multiplex deviation,
±
Peak / 2
Range:
0 Hz to +96 kHz
Default unit: Hz
<6_MultDevPos>
Multiplex deviation, +Peak
Range:
-96 kHz to +96 kHz
Default unit: Hz
<7_MultDevNeg>
Multiplex deviation,
–
Peak
Range:
-96 kHz to +96 kHz
Default unit: Hz
<8_MultDevRMS>
Multiplex deviation, RMS
Range:
0 Hz to +96 kHz
Default unit: Hz
Example:
See
Performing Single Shot RF Measurements
Usage:
Query only
Firmware/Software:
V1.0.15.20
FETCh:FMSTereo:MEAS<i>:MEValuation:RFCarrier:MINimum?
READ:FMSTereo:MEAS<i>:MEValuation:RFCarrier:MINimum?
CALCulate:FMSTereo:MEAS<i>:MEValuation:RFCarrier:MINimum?
Returns the minimum "RF Carrier" results.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.