Preparation for Use
R&S
®
EB510
8
Getting Started 4091.7338.02 ─ 01
1.2.2
Rack Mounting
Ambient temperature
The R&S
EB510 should be used in an area where the ambient temperature
does not exceed –10
°C to +55
°C (EB510 without front control panel) or 0
°C
to 55
°C (EB510 with front control panel), respectively. The R&S
EB510 is
fan-cooled and must be installed with sufficient space along the sides to
ensure a free flow of air. Make sure that there is sufficient space for hot air to
escape from the R&S
EB510. To ensure sufficient cooling do not attach tele-
scopic rails to the sides of the unit.
1.2.3
In-vehicle Mounting
For use in vehicles, the R&S
EB510 can be powered directly from the vehicle's
battery via the DC input.
1.2.4
EMI Protective Measures
In order to avoid electromagnetic interference (EMI), the R&S
EB510 may only be
operated when it is closed and all shielding covers are in place. Use only appropriate
shielded signal and control cables with proper termination.
1.2.5
Connecting the R&S
EB510 to the Power Supply
Connect the R&S
EB510 observing the following sections and instructions for use.
The R&S
EB510 is suitable only for DC operation.
1.2.5.1
Connecting to the Power Adapter
The R&S
EB510 is connected to the AC supply 100
V to 240
V via an external AC/
DC power adapter and to the socket X1 (10
VDC to 32
VDC) on the rear panel.
Recommended connector: Neutrik® Speakon® NL4FX (see the figure below).