Connecting to power

The product is an overvoltage category II product. Connect the product to a fixed
installation used to supply energy-consuming equipment such as household
appliances and similar loads. Keep in mind that electrically powered products
have risks, such as electric shock, fire, personal injury or even death.

Take the following measures for your safety:

Before switching on the product, ensure that the voltage and frequency indica-
ted on the product match the available power source. If the power adapter
does not adjust automatically, set the correct value and check the rating of the
fuse.

Only use the power cable delivered with the product. It complies with country-
specific safety requirements. Only insert the plug into an outlet with protective
conductor terminal.

Only use intact cables and route them carefully so that they cannot be dam-
aged. Check the power cables regularly to ensure that they are undamaged.
Also ensure that nobody can trip over loose cables.

If the product needs an external power supply, use the power supply that is
delivered with the product or that is recommended in the product documenta-
tion or a power supply that conforms to the country-specific regulations.

Only connect the product to a power source with a fuse protection of maxi-
mum 20

 

A.

Ensure that you can disconnect the product from the power source at any
time. Pull the power plug to disconnect the product. The power plug must be
easily accessible. If the product is integrated into a system that does not meet
these requirements, provide an easily accessible circuit breaker at the system
level.

Connecting headphones

Take the following measures to prevent hearing damage. Before using head-
phones, check the volume and reduce it if necessary. If you monitor varying sig-
nal levels, take off the headphones and wait until the signal has settled. Then
adjust the volume.

Cleaning the product

Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that
the casing is not waterproof. Do not use liquid cleaning agents.

Safety Instructions

Summary of Contents for 1328.6660K02

Page 1: ...R S FPC Spectrum Analyzer Getting Started 1328740902 Version 05 L 92...

Page 2: ...de schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the...

Page 3: ...e information is provided in many languages as printed Safety Instructions The printed Safety Instructions are delivered with the product Throughout the documentation safety instructions are provided...

Page 4: ...d you can operate the product up to an altitude of 2000 m above sea level The product is suitable for pollution degree 2 environ ments where nonconductive contamination can occur For more information...

Page 5: ...ularly to ensure that they are undamaged Also ensure that nobody can trip over loose cables If the product needs an external power supply use the power supply that is delivered with the product or tha...

Page 6: ...the casing inform about Personal safety see Meaning of safety labels on page 6 Product and environment safety see Table 1 1 Identification of the product see Device ID on page 19 Table 1 1 Labels rega...

Page 7: ...ts with a serial number 200000 have an internal Wi Fi module You can access the regulatory information for this module in the firmware of the R S FPC 1 Press the Setup key The R S FPC opens the Instru...

Page 8: ...S FPC user manual there is a separate user manual for the R S InstrumentView software package This manual contains a description of all features of the R S InstrumentView software package The online...

Page 9: ...ense texts of the used open source software www rohde schwarz com manual fpc The open source acknowledgement is also integrated into the firmware chm for mat You can export the file to a memory stick...

Page 10: ...13 Connecting AC power 14 Turning the R S FPC on and off 14 3 1 Lifting and carrying See Lifting and carrying the product on page 4 3 2 Unpacking and checking the instrument 1 Unpack the R S FPC caref...

Page 11: ...en in the data sheet under Gen eral data Class B equipment is suitable for use in Residential environments Environments that are directly connected to a low voltage supply network that supplies reside...

Page 12: ...To prepare the rack 1 Observe the requirements and instructions in Setting up the product on page 4 2 NOTICE Insufficient airflow can cause overheating and damage the product Design and implement an e...

Page 13: ...levels are within the specified ranges defined in the data sheet In particular pay attention to the following limits to avoid damage to the R S FPC Do not overload the RF input and keep within the max...

Page 14: ...afety class EN61010 Therefore it may only be connected to an outlet that has a ground contact The AC power supply has the following characteristics Line voltage 100 V AC to 240 V AC Line frequency 50...

Page 15: ...er switch on the rear panel of the R S FPC position O The instrument is no longer supplied with AC power To disconnect from power The product is in the standby state 1 NOTICE Risk of data loss If you...

Page 16: ...panel of the R S FPC 1 USB ports type A 2 Headphone jack 3 Softkeys 4 Signal source output 5 Function keys and alphanumeric keypad 6 RF Input 7 Power switch Power switch The power switch turns the R S...

Page 17: ...0 ports on the front panel type A allow you to connect devices like memory sticks Function keys and alphanumeric keypad The function keys provide access to the measurement settings and functions The...

Page 18: ...ce 2 LAN 3 USB port type B 4 Power supply Power supply The AC power supply and main power switch are located in a unit on the rear panel of the instrument The main power switch has the following state...

Page 19: ...printouts or data transfer The assignment of the RJ 45 connector supports twisted pair category 5 UTP STP cables in a star configuration UTP stands for unshielded twisted pair and STP for shielded twi...

Reviews: