Rohde & Schwarz 1328.6660K02 Getting Started Download Page 19

Instrument tour

R&S

®

FPC

19

Getting Started 1328.7409.02 ─ 05

When you are using the connector as a trigger input, you can trigger measure-
ments with an external trigger. For more information about triggered measure-
ments, refer to the user manual.

Alternatively, you can use the connector to connect a 10

 

MHz reference signal to

synchronize the frequency with the external reference. Note that the reference
signal must be stronger than 0

 

dBm.

LAN

The LAN interface allows you to connect the R&S

 

FPC to a local network for

remote control, printouts or data transfer. The assignment of the RJ-45 connector
supports twisted-pair category 5 UTP/STP cables in a star configuration (UTP
stands for 

unshielded twisted pair

, and STP for 

shielded twisted pair

).

USB port (type B)

The USB port (type B) allows you to connect the R&S

 

FPC to a computer and

establish a remote control connection.

Device ID

The unique device identifier is provided as a barcode sticker on the rear panel of
the R&S

 

FPC.

It consists of the serial number and a 2-character checksum.

The device ID is defined as the following example:
1310.3004.02-123456-ab
1310.3004.02 = Order number
123456 = Serial number
ab = Checksum
The instrument name is required to establish a connection to the instrument
in a LAN.

Rear panel

Summary of Contents for 1328.6660K02

Page 1: ...R S FPC Spectrum Analyzer Getting Started 1328740902 Version 05 L 92...

Page 2: ...de schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the...

Page 3: ...e information is provided in many languages as printed Safety Instructions The printed Safety Instructions are delivered with the product Throughout the documentation safety instructions are provided...

Page 4: ...d you can operate the product up to an altitude of 2000 m above sea level The product is suitable for pollution degree 2 environ ments where nonconductive contamination can occur For more information...

Page 5: ...ularly to ensure that they are undamaged Also ensure that nobody can trip over loose cables If the product needs an external power supply use the power supply that is delivered with the product or tha...

Page 6: ...the casing inform about Personal safety see Meaning of safety labels on page 6 Product and environment safety see Table 1 1 Identification of the product see Device ID on page 19 Table 1 1 Labels rega...

Page 7: ...ts with a serial number 200000 have an internal Wi Fi module You can access the regulatory information for this module in the firmware of the R S FPC 1 Press the Setup key The R S FPC opens the Instru...

Page 8: ...S FPC user manual there is a separate user manual for the R S InstrumentView software package This manual contains a description of all features of the R S InstrumentView software package The online...

Page 9: ...ense texts of the used open source software www rohde schwarz com manual fpc The open source acknowledgement is also integrated into the firmware chm for mat You can export the file to a memory stick...

Page 10: ...13 Connecting AC power 14 Turning the R S FPC on and off 14 3 1 Lifting and carrying See Lifting and carrying the product on page 4 3 2 Unpacking and checking the instrument 1 Unpack the R S FPC caref...

Page 11: ...en in the data sheet under Gen eral data Class B equipment is suitable for use in Residential environments Environments that are directly connected to a low voltage supply network that supplies reside...

Page 12: ...To prepare the rack 1 Observe the requirements and instructions in Setting up the product on page 4 2 NOTICE Insufficient airflow can cause overheating and damage the product Design and implement an e...

Page 13: ...levels are within the specified ranges defined in the data sheet In particular pay attention to the following limits to avoid damage to the R S FPC Do not overload the RF input and keep within the max...

Page 14: ...afety class EN61010 Therefore it may only be connected to an outlet that has a ground contact The AC power supply has the following characteristics Line voltage 100 V AC to 240 V AC Line frequency 50...

Page 15: ...er switch on the rear panel of the R S FPC position O The instrument is no longer supplied with AC power To disconnect from power The product is in the standby state 1 NOTICE Risk of data loss If you...

Page 16: ...panel of the R S FPC 1 USB ports type A 2 Headphone jack 3 Softkeys 4 Signal source output 5 Function keys and alphanumeric keypad 6 RF Input 7 Power switch Power switch The power switch turns the R S...

Page 17: ...0 ports on the front panel type A allow you to connect devices like memory sticks Function keys and alphanumeric keypad The function keys provide access to the measurement settings and functions The...

Page 18: ...ce 2 LAN 3 USB port type B 4 Power supply Power supply The AC power supply and main power switch are located in a unit on the rear panel of the instrument The main power switch has the following state...

Page 19: ...printouts or data transfer The assignment of the RJ 45 connector supports twisted pair category 5 UTP STP cables in a star configuration UTP stands for unshielded twisted pair and STP for shielded twi...

Reviews: