Safety and regulatory information

R&S

®

FPC

4

Getting Started 1328.7409.02 ─ 05

Never open the casing of the product. Only service personnel authorized by
Rohde

 

&

 

Schwarz are allowed to repair the product. If any part of the product is

damaged or broken, stop using the product. Contact Rohde

 

&

 

Schwarz customer

service at 

http://www.customersupport.rohde-schwarz.com

.

Lifting and carrying the product

The maximum weight of the product is provided in the data sheet. To move the
product safely, you can use lifting or transporting equipment such as lift trucks
and forklifts. Follow the instructions provided by the equipment manufacturer.

Choosing the operating site

Only use the product indoors. The product casing is not waterproof. Water that
enters can electrically connect the casing with live parts, which can lead to elec-
tric shock, serious personal injury or death if you touch the casing. If
Rohde

 

&

 

Schwarz provides accessories designed for your product, e.g. a carrying

bag, you can use the product outdoors.

Unless otherwise specified, you can operate the product up to an altitude of
2000

 

m above sea level. The product is suitable for pollution degree

 

2 environ-

ments where nonconductive contamination can occur. For more information on
environmental conditions such as ambient temperature and humidity, see the
data sheet.

Setting up the product

Always place the product on a stable, flat and level surface with the bottom of the
product facing down. If the product is designed for different positions, secure the
product so that it cannot fall over.

If the product has foldable feet, always fold the feet completely in or out to ensure
stability. The feet can collapse if they are not folded out completely or if the prod-
uct is moved without lifting it. The foldable feet are designed to carry the weight of
the product, but not an extra load.

If stacking is possible, keep in mind that a stack of products can fall over and
cause injury.

If you mount products in a rack, ensure that the rack has sufficient load capacity
and stability. Observe the specifications of the rack manufacturer. Always install
the products from the bottom shelf to the top shelf so that the rack stands
securely. Secure the product so that it cannot fall off the rack.

Safety Instructions

Summary of Contents for 1328.6660K02

Page 1: ...R S FPC Spectrum Analyzer Getting Started 1328740902 Version 05 L 92...

Page 2: ...de schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the...

Page 3: ...e information is provided in many languages as printed Safety Instructions The printed Safety Instructions are delivered with the product Throughout the documentation safety instructions are provided...

Page 4: ...d you can operate the product up to an altitude of 2000 m above sea level The product is suitable for pollution degree 2 environ ments where nonconductive contamination can occur For more information...

Page 5: ...ularly to ensure that they are undamaged Also ensure that nobody can trip over loose cables If the product needs an external power supply use the power supply that is delivered with the product or tha...

Page 6: ...the casing inform about Personal safety see Meaning of safety labels on page 6 Product and environment safety see Table 1 1 Identification of the product see Device ID on page 19 Table 1 1 Labels rega...

Page 7: ...ts with a serial number 200000 have an internal Wi Fi module You can access the regulatory information for this module in the firmware of the R S FPC 1 Press the Setup key The R S FPC opens the Instru...

Page 8: ...S FPC user manual there is a separate user manual for the R S InstrumentView software package This manual contains a description of all features of the R S InstrumentView software package The online...

Page 9: ...ense texts of the used open source software www rohde schwarz com manual fpc The open source acknowledgement is also integrated into the firmware chm for mat You can export the file to a memory stick...

Page 10: ...13 Connecting AC power 14 Turning the R S FPC on and off 14 3 1 Lifting and carrying See Lifting and carrying the product on page 4 3 2 Unpacking and checking the instrument 1 Unpack the R S FPC caref...

Page 11: ...en in the data sheet under Gen eral data Class B equipment is suitable for use in Residential environments Environments that are directly connected to a low voltage supply network that supplies reside...

Page 12: ...To prepare the rack 1 Observe the requirements and instructions in Setting up the product on page 4 2 NOTICE Insufficient airflow can cause overheating and damage the product Design and implement an e...

Page 13: ...levels are within the specified ranges defined in the data sheet In particular pay attention to the following limits to avoid damage to the R S FPC Do not overload the RF input and keep within the max...

Page 14: ...afety class EN61010 Therefore it may only be connected to an outlet that has a ground contact The AC power supply has the following characteristics Line voltage 100 V AC to 240 V AC Line frequency 50...

Page 15: ...er switch on the rear panel of the R S FPC position O The instrument is no longer supplied with AC power To disconnect from power The product is in the standby state 1 NOTICE Risk of data loss If you...

Page 16: ...panel of the R S FPC 1 USB ports type A 2 Headphone jack 3 Softkeys 4 Signal source output 5 Function keys and alphanumeric keypad 6 RF Input 7 Power switch Power switch The power switch turns the R S...

Page 17: ...0 ports on the front panel type A allow you to connect devices like memory sticks Function keys and alphanumeric keypad The function keys provide access to the measurement settings and functions The...

Page 18: ...ce 2 LAN 3 USB port type B 4 Power supply Power supply The AC power supply and main power switch are located in a unit on the rear panel of the instrument The main power switch has the following state...

Page 19: ...printouts or data transfer The assignment of the RJ 45 connector supports twisted pair category 5 UTP STP cables in a star configuration UTP stands for unshielded twisted pair and STP for shielded twi...

Reviews: