background image

Roger Access Control System 

PRT12MF-DES, PRT84MF and PRT82MF readers 

Operating Manual 

Firmware version: v1.0.8 or newer 

Hardware version: 1.0 

Document version: Rev. C 

 

 

 

This document refers to the following products: 

PRT12MF-DES, PRT12MF-DES-BK, PRT82MF, PRT82MF-BK, PRT84MF and PRT84MF-BK 

 
 
 

 
 

 

Summary of Contents for PRT12MF-DES

Page 1: ...S PRT84MF and PRT82MF readers Operating Manual Firmware version v1 0 8 or newer Hardware version 1 0 Document version Rev C This document refers to the following products PRT12MF DES PRT12MF DES BK PRT82MF PRT82MF BK PRT84MF and PRT84MF BK ...

Page 2: ...tion 4 1 3 2 PCN section 4 1 3 3 RCN format rules 5 2 Operating modes and output formats 6 2 1 RACS CLK DTA mode 7 2 2 Wiegand mode 7 3 Reader configuration 8 3 1 RogerVDM configuration 8 3 2 Manual programming of operating mode 13 3 3 Memory Reset 16 4 Installation guidelines 16 5 Firmware update 20 6 Technical specification 21 7 Ordering 22 8 Product history 22 ...

Page 3: ...iegand mode Adjustable keypad backlight Two function keys PRT12MF DES Tamper contact Programming from PC RogerVDM software 0 5m connection cable Outdoor use CE Mark 1 3 Card number RCN Returned Card Number which is transmitted by reader to access controller consists of two sections corresponding to two numbers stored on MIFARE card i e read only CSN Chip Serial Number and custom PCN Programmed Car...

Page 4: ...on PCN section can be a part of RCN and it stored on card s memory This number can be defined and modified by administrator of the system PCN is stored in specified sector and block of memory and it is encrypted with selected key The location of PCN is specified by Sector type parameter in RogerVDM software during low level configuration of PRT reader The parameter can be NONE SSN MAD or Desfire f...

Page 5: ... 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ASCII 0 1 2 3 4 5 6 7 8 9 A B C D E F BIN 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h 41h 42h 43h 44h 45h 46h Example If FBP 2 LBP 10 Format ASCII HEX and data block is as below then PCN is 23456789A FBP LBP Pos 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ASCII 0 1 2 3 4 5 6 7 8 9 A B C D E F BIN 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h 41h 42h 43h 44h 45h 46h Example If FB...

Page 6: ...Sector type None and the parameter Serial number length CSNL is in range of 1 7 depending on the number of bytes intended for identification 2 The RCN returned by reader includes only PCN section if the parameter Sector Type None and the parameter Serial number length CSNL 0 3 If the actual RCN is longer than the maximal length for particular output format then the reader cuts leading bytes when t...

Page 7: ... DTA mode LED and buzzer are controlled by communication protocol and no additional control lines for this purpose are necessary In case of communication loss with host controller all reader LEDs are flashing Fig 1 Connection of reader to access controller RACS CLK DTA 2 2 Wiegand mode In this mode reader transmits data using CLK and DTA lines which are respectively connected to controller s DATA0...

Page 8: ... be connected to PC via RUD 1 interface fig 3 and programmed by means of RogerVDM software which is available at www roger pl Fig 3 Connection of reader to RUD 1 interface Fig 4 Location of service contacts Connection method 1 Connect the reader to RUD 1 interface fig 3 and connect the RUD 1 to computer s USB port 2 Place jumper on MEM contacts fig 4 3 Restart the reader switch power supply off an...

Page 9: ... 1 interface Note Do not read any cards nor press reader keypad when reader is configured with RogerVDM Fig 5 Select Device window view Table 1 Configuration parameters Parameter name Range Description General Name 16 ASCII characters Device description any comment Communication settings Operating mode 0 RACS CLK DTA 1 Wiegand Parameter defines data output format which reader uses for communicatio...

Page 10: ...s Optical signalisation LED SYSTEM control input for Wiegand mode 0 None 1 IN1 2 IN2 Defines the input line which will control LED SYSTEM when reader operates in Wiegand mode LED OPEN control input for Wiegand mode 0 None 1 IN1 2 IN2 Defines the input line which will control LED OPEN when reader operates in Wiegand mode LED STATUS control input for Wiegand mode 0 None 1 IN1 2 IN2 Defines the input...

Page 11: ...g until previous PIN card is transmitted to controller Clear card PIN buffer timeout s 0 64 Defines time from the last card PIN entry till moment when card PIN buffer is automatically erased Buffer overflow signalisation on LED SYSTEM 0 Off 1 On When option is active reader will signal on LED SYSTEM that card PIN buffer overflow occurred Card PIN encryption 0 Off 1 On When option is active the car...

Page 12: ...ion ID AID 0000 FFFFF Specifies AID number Application Identifier which indicates sector where PCN number is stored by default Roger AID number is 5156 Block ID 0 15 Specifies block number within sector where PCN code is stored Key type 0 A 1 B Specifies key type used to encrypt data stored on the card Key 00000000000000000 000000000000000 F FFFFFFFFFFFFFFFFFF FFFFFFFFFFFF 16 bytes key used to enc...

Page 13: ...ys contain 16 bytes 3 2 Manual programming of operating mode The operating mode of the reader can be configured manually without RogerVDM software Manual programming procedure 1 Remove all connections from CLK and DTA lines 2 Put jumper on MEM contacts see fig 4 3 Restart the reader switch power supply off and on or short RST contacts for a moment 4 While LED SYSTEM is flashing enter three digits ...

Page 14: ...rmat Each key pressed is buffered in reader s memory with a press of a key reader transmits entire PIN code The PIN code is transmitted as a binary number X 2 Each key pressed is transmitted separately as 4 bit number plus 2 control bits Each key pressed is immediately transmitted to the host controller as a sequence of 6 bits EXXXXP where XXXX represents the code of the pressed key supplemented b...

Page 15: ...g PIN transmitted as Wiegand 26 bit stream with control bits 1 6 keys long PIN each key represented by 4 bit long codes key codes according to table B Reader sends data after six keys are pressed or earlier when key is pressed Key s buffer is cleared if no keys have not been entered within programmed timeout Examples Keys entered 1234 code transmitted 001234 Keys entered 123456 code transmitted 12...

Page 16: ...gs so that tamper lever touched the surface and firmly pressed the tamper switch The reader enclosure consists of a front and rear panel Before installation it is necessary to separate them by means of included key or flat screwdriver according to fig 6 It is recommended to install PRT82MF reader on a flush type box 60mm diameter PRT12MF DES reader is delivered with additional extended base panel ...

Page 17: ...closure disassembly Table 4 Connection wires Name Wire colour Description 12V Red Supply plus GND Blue Supply minus CLK Green RACS CLK DTA communication line CLK DTA Brown RACS CLK DTA communication line DTA IN1 Yellow IN1 input IN2 Pink IN2 input TAMP Grey Tamper switch contacts TAMP White ...

Page 18: ...PRT12MF DES PRT82MF PRT84MF Operating Manual doc 2018 08 23 18 23 Fig 7 Dimensions and tamper details standard low profile bottom enclosure ...

Page 19: ...PRT12MF DES PRT82MF PRT84MF Operating Manual doc 2018 08 23 19 23 Fig 8 Dimensions and tamper details standard high profile bottom enclosure ...

Page 20: ... 1 communication interface The file with latest firmware is available at www roger pl Firmware update procedure 1 Connect reader to RUD 1 interface according to fig 3 2 Put jumper on FDM contacts fig 4 3 Run RogerVDM application 4 Choose Tools Update Firmware 5 Select device type communication port for RUD 1 and path to firmware file hex 6 Click Update and follow the instructions ...

Page 21: ...Tamper protection Isolated 50mA 24V contacts shorted when enclosure is closed Proximity cards 13 56MHz according to ISO14443A and MIFARE Reading range Up to 7 cm for ISO MIFARE Ultralight Classic Up to 5 cm for ISO MIFARE DESFire EV1 Plus Note Reading distance is defined for good quality proximity cards placed in optimal position against the reader For all readers the optimal position for card rea...

Page 22: ... 56 MHz ISO IEC 14443A MIFARE Ultralight Classic DESFire EV0 EV1 and Plus outdoor reader dark grey enclosure 0 5m connection cable PRT82MF Dark grey enclosure sensor keypad PRT82MF BK Dark grey enclosure without keypad PRT84MF Dark grey enclosure sensor keypad two function keys PRT84MF BK Dark grey enclosure without keypad RUD 1 Portable communication interface USB RS485 with 12VDC output 8 PRODUC...

Page 23: ...oints of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum G...