PRT12MF-DES PRT82MF PRT84MF Operating Manual.doc
2018-08-23
13/23
File ID (FID)
0..32
Defines file number in which RCN is placed. For
DESFire EV0 cards it is acceptable number from 0
to 16, however in EV1 cards – numbers from 0 to
32.
Communication
protection level
0 – Plain
1
–
Data
authentication
by
MAC
2 – Full encryption
Defines type of encryption between card and
reader.
Key number
0..13
Defines key ID of application which is used to
encrypt file.
Key type
0 – TDES Crypto
DESFire Native Mode
1 – TDES Crypto
Standard Mode
2 – 3KTDES Crypto
3 – AES128 Crypto
Defines key type used to encrypt data on card.
Key
00000000000000000
000000000000000..F
FFFFFFFFFFFFFFFFFF
FFFFFFFFFFFFF
Key used to encrypt data on card. 3KTDES key
type contains 24 bytes, TDES and AES keys
contain 16 bytes.
3.2 Manual programming of operating mode
The operating mode of the reader can be configured manually without RogerVDM software.
Manual programming procedure:
1.
Remove all connections from CLK and DTA lines.
2.
Put jumper on MEM contacts (see fig. 4).
3.
Restart the reader (switch power supply off and on or short RST contacts for a moment).
4.
While LED SYSTEM is flashing enter three digits which will select required operating mode
(table 2).
5.
Remove jumper from MEM contacts and restart the reader.
If Wiegand operating mode is selected then by default IN1 input is configured to control LED OPEN
while IN2 is configured to control buzzer. If necessary these settings can be changed by means
of RogerVDM software.
Table 2. Operating mode codes
Code
Operating mode
000
RACS CLK/DTA address ID=0
001
RACS CLK/DTA address ID=1
002
RACS CLK/DTA address ID=2
003
RACS CLK/DTA address ID=3
10x
26 bit Wiegand
11x
34 bit Wiegand
12x
42 bit Wiegand