PRT Series Readers
The PRT reader’s family developed and manufactured by the Roger. Each member
of PRT series readers can be connected to the external access controller (this is
called
Online
mode) or operate as stand-alone unit (this is called
Offline
mode).
Restart
The scenario when device goes through initialization procedure, the same as during
power up of a unit.
Roger Access Control System (RACS)
The access control system which consists of PR series access controllers developed
and manufactured by Roger.
Access Control Unit (ACU)
The logic device which provides access control, usually it is an access controller.
XM-2 I/O Extension Module
The remote I/O extension module for RACS system. The XM-2 provides two NO/NC
inputs and two relay type outputs.
Full Stand-alone mode
The operation mode in which reader independently controls a door passage. When
in
Full Stand-alone mode
PRT12 requires the remote XM-2 extension module,
optionally it may operate with additional PRT series reader (two-way passage).
Simple Stand-alone mode
The operation mode in which reader independently controls a door passage. When
in
Simple Stand-alone mode
PRT12 uses its internal I/O lines as general purpose
I/Os and is not capable to operate with XM-2 I/O module nor additional PRT reader.
4.
General
4.1.
Designed function
The PRT12 terminal has been designed for use in access control installations to
enable user identification via EM 125 kHz UNIQUE standard proximity cards and/or
PIN codes.
A reader can be configured for
Stand-alone
mode (alternatively called
Offline
mode)
or for use with an external access control unit (ACU) supporting compatible data
interface formats (
Online
mode).
The PRT12 configured for
Online
mode works as a slave unit serving a sole purpose
of reading cards and/or entering a PIN codes then providing subsequent
transmission of such collected data to the host ACU for further processing.
The PRT12 terminal offers several data transmission formats available for use in
Online
mode which includes the popular
Wiegand
and
Magstripe
(i.e. simulation of
an output of a magnetic card reader) data protocols.
When configured for
Stand-alone
operation (
Offline
mode), the PRT12 reader
independently (i.e. autonomously) controls the supervised door access point. For
this mode the reader offers two installation configurations — first of them uses the