User
or
Installer Programming
mode. If you don’t program card nor PIN you will be
not able later to enter required programming mode.
7 . 4 . 1 .
F a c t o r y d e f a u l t s e t t i n g s
Once the
Memory Reset
is competed the reader restores the following, factory-
shipped, default settings:
Door unlock time
: 4 sec.
Door open timeout
: 12 sec.
Line IN1 on the reader:
Door Contact
input
Line IN1 on the XM-2 module:
Exit Button
input (momentary)
Line IN2 on the XM-2 module:
Arming Disabled
input
CLK or REL1 line function:
Door Lock
output
DTA or REL2 line function:
Disarmed Mode
output
User identification mode on the primary reader:
Card or PIN
User identification mode on the secondary reader:
Card or PIN
Option:
Door alarm indication on internal buzzer
, option OFF
Option:
Access disabled when reader armed,
option OFF
7.5.
Installer Programming mode
Use this mode to configure various functionalities of the PRT12 reader. You can
enter it by entering your INSTALLER PIN or reading INSTALLER card. Once in this
mode the LED OPEN turns on and the LED STATUS lights in green.
The reader placed in this mode waits for the installer to sequentially enter thirteen
digits labeled C1…C13. After entering the last one the reader saves all entered
data, then exits the programming mode and returns to the operation mode it was
in before entering
Installer Programming
.
Note: If you don’t press any key within 20 s time, reader will automatically leave
the programming mode.
Depending on the operation mode selected for the reader (either
Simple Stand-
alone Mode
or
Full Stand-alone
mode), the configuration digits C5 and C6 may have
different effects: for
Simple Stand-alone
mode they configure the reader’s CLK and
DTA internal lines, while for
Full Stand-alone
mode they program functions of the
REL1 and REL2 relay outputs located on XM-2 I/O extension module.
Note: The IN1 located on the reader always operates as an input. The reader’s CLK
and DTA lines can be used either as inputs or outputs. Still, the REL1 and REL 2
lines may function only as outputs. Also, the IN1 and IN2 on the XM-2 operate as
inputs only. If you try to program the REL1 and REL2 lines to some input function,
they will not work at all.