![Roger PRT12 v1.3 Installation And Programming Manual Download Page 26](http://html.mh-extra.com/html/roger/prt12-v1-3/prt12-v1-3_installation-and-programming-manual_1477237026.webp)
PRT12 v1.3 fv75.6 EN Rev.D.doc
10/22/2007
_________________________________________________________________________________________
Page 26 of 40
10.
Appendix
Connection Wires Assignments
Offline mode
Wire
Color
Label
Simple Stand-alone
mode
Full Stand-alone
mode
Online mode
(unit connected to host ACU)
Red
+12V
Supply input plus.
Blue
GND
Supply input minus.
Green
CLK
Can be configured as
an input or output.
CLOCK
communication line.
DATA 0 line for
Wiegand
formats
CLOCK for
Magstripe
and RACS
formats.
Brown
DTA
Can be configured as
an input or output.
DATA
communication line.
DATA 1 line for
Wiegand
formats
DATA for
Magstripe
and RACS
formats.
Yellow
IN1
Input line, can be configured to several
available functions).
In
Wiegand
and
Magstripe
formats,
the IN1 line activated by shorting it
with the supply minus. When IN1 is
triggered it turns the LED OPEN to
on and also activates acoustic signal
on the internal buzzer.
Grey
White
TAMP
Isolated, tamper switch contacts, when case is closed contacts are shorted.
Pink
NC
Not used (reserved for further use)
Shield
None
Cable shield is internally connected with supply minus (GND)
Technical Specification
Input voltage
10...15 VDC
Current consumption
Avg. 60 mA
Anti-sabotage protection
(Tamper)
NC contact, 50mA/24V, IP67
Reading distance
Up to 12 cm for ISO cards (depends on cards).
Proximity cards
EM UNIQUE 125 kHz, ASK modulation, 64 bits (compatible with
EM4100/4102).
Communication distance
Between ACU and PRT reader in ONLINE mode: max. 150 m.
Between main PRT reader and second PRT reader: max. 150 m.
Between main PRT reader and XM-2 extension module: max. 150 m.
Environmental class
(according to EN 50131-1)
Class IV, Outdoor-General, temperature: -25°C- +60°C, relative humidity:
10 to 95% (non-condensing).
Ingress protection
IP 65
Dimensions
H100 X W40 X D25 mm
Weight
~150 g
Approvals
CE