background image

MCT12E Operating Manual 

  

05.10.2020 

 

9/14 

 

 

Fig. 7 Typical connection diagram for the 

–IO version  terminal and MC16 access controller 

4.

 

C

ONFIGURATION

 

Low level configuration (RogerVDM) 

The purpose of low level configuration is to prepare device for operation in RACS 5 system. 
 
Programming procedure with RogerVDM software: 

1.  Connect the reader to RUD-1 interface (fig. 8) and connect the RUD-

1 to computer’s USB port. 

2.  Start  RogerVDM  program,  select 

MCT

  device,  firmware  version, 

RS485

  communication  channel  and 

serial port with RUD-1 interface. 

3.  Click 

Connect,

 the program will establish connection and will automatically display 

Configuration

 tab. 

4.  Enter unoccupied RS485 address in range of 100-115 and other settings according to requirements of 

specific installation. 

5.  Click 

Send to Device

 to update the configuration of reader. 

6.  Optionally make a backup by clicking 

Send to File… 

and saving settings to file on disk. 

7.  In the top menu select 

Device->Disconnect.

 

8.  Disconnect reader from RUD-1 interface. 

Note: Do not read any cards nor press keypad when reader is configured with RogerVDM. 

Summary of Contents for MCT12E

Page 1: ...Roger Access Control System MCT12E Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Page 2: ...ly IO versions Power supply The terminal requires power supply voltage in range of 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or f...

Page 3: ...matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twiste...

Page 4: ...icates access granting LED SYSTEM Orange LED indicates card reading and can signal other system functions including device malfunction Note Synchronic pulsing of LED indicators signifies lost communic...

Page 5: ...rds EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical characteristics...

Page 6: ...85 bus line B CLK White Green CLK line DTA Green Yellow DTA line TMP Yellow Pink Tamper contact TMP Grey Grey Tamper contact IO1 Yellow brown IO1 output line IO2 Green brown IO2 output line REL1 NC Gr...

Page 7: ...MCT12E Operating Manual 05 10 2020 7 14 Fig 5 MCT12E installation...

Page 8: ...must be connected with any wire Device can be cleaned by means of wet cloth and mild detergent without abrasive components In particular do not clean with alcohols solvents petrol disinfectants acids...

Page 9: ...MCT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 En...

Page 10: ...h readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default value...

Page 11: ...disabled Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comm...

Page 12: ...the next digit Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3...

Page 13: ...5 bus between controller and reader IP Code IP65 Environmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dim...

Page 14: ...ctric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste cont...

Reviews: