background image

MCT12E Operating Manual 

  

05.10.2020 

 

13/14 

 

Current 

consumption 

(average) 

MCT12E/MCT12E-IO:   

 

~50 mA 

MCT12E-BK/MCT12E-BK-IO:  

~40 mA 

Inputs 

Three  (IN1..IN3)  NO/NC  inputs  internally  connected  to  the  power  supply  plus 
through a 15kΩ resistor, approx. 3.5V triggering level 

Relay output 

Relay output (REL1) with single NO/NC contact, 30V/1.5A DC/AC max. load 

Transistor outputs 

Two (IO1, IO2) open collector outputs, 15VDC/1A max. load 

Tamper protection 

Isolated 50mA/24V contacts, shorted when enclosure is closed 

Proximity cards 

EM 125 kHz UNIQUE according to EM4100/4102 

Reading range 

Up to 7 cm 

Distance 

1200m maximal cable length for RS485 bus between controller and reader 

IP Code 

IP65 

Environmental 

class 

(according 

to 

EN 

50133-1) 

Class  IV,  outdoor  general  conditions,  temperature:  -

25°C  to  +60°C,  relative 

humidity: 10 to 95% (no condensation) 

Dimensions H x W x D  

152,5 x 46 x 23(35) mm  

Weight 

~150g 

Certificates 

CE 

 

7.

 

O

RDERING INFORMATION

 

Table 7. Ordering information 

MCT12E-BK 

EM 125 kHz access terminal 

MCT12E-BK-IO 

EM 125 kHz access terminal; on-board I/Os 

MCT12E 

EM 125 kHz access terminal with keypad 

MCT12E-IO 

EM 125 kHz access terminal with keypad; on-board I/Os 

RUD-1 

Portable  USB-RS485  communication  interface  dedicated  to  ROGER  access 
control devices 

 

8.

 

P

RODUCT HISTORY

 

Table 8. Product history 

Version 

Date 

Description 

MCT12E v1.0 

01/2015 

The first commercial version of product 

MCT12E v1.1 

12/2015 

Minor modifications of power supply and RS485 circuits 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MCT12E

Page 1: ...Roger Access Control System MCT12E Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Page 2: ...ly IO versions Power supply The terminal requires power supply voltage in range of 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or f...

Page 3: ...matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twiste...

Page 4: ...icates access granting LED SYSTEM Orange LED indicates card reading and can signal other system functions including device malfunction Note Synchronic pulsing of LED indicators signifies lost communic...

Page 5: ...rds EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical characteristics...

Page 6: ...85 bus line B CLK White Green CLK line DTA Green Yellow DTA line TMP Yellow Pink Tamper contact TMP Grey Grey Tamper contact IO1 Yellow brown IO1 output line IO2 Green brown IO2 output line REL1 NC Gr...

Page 7: ...MCT12E Operating Manual 05 10 2020 7 14 Fig 5 MCT12E installation...

Page 8: ...must be connected with any wire Device can be cleaned by means of wet cloth and mild detergent without abrasive components In particular do not clean with alcohols solvents petrol disinfectants acids...

Page 9: ...MCT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 En...

Page 10: ...h readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default value...

Page 11: ...disabled Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comm...

Page 12: ...the next digit Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3...

Page 13: ...5 bus between controller and reader IP Code IP65 Environmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dim...

Page 14: ...ctric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste cont...

Reviews: