MCT12E Operating Manual 

  

05.10.2020 

 

8/14 

 

Note:  New  device  is  assembled  with  standard  back  panel  with  23mm  thickness  but  additional  back  panel 
with 35mm thickness is included. Such panel can be used if more space for connection cable is needed and 
it may also improve card reading distance if the terminal is mounted on metal surface. 

Installation guidelines 

  The  terminal  should  be  mounted  on  a  vertical  structure  (wall)  away  from  sources  of  heat  and 

moisture. 

  Front  panel  should  be  attached  in  such  way  as  the  tamper  detector  (fig.  4)  would  firmly  press  the 

back panel. 

  All electrical connections should be done with disconnected power supply. 

  If  the  terminal  and  controller  are  not  supplied  from  the  same  PSU  then  GND  terminals  of  both 

devices must be connected with any wire. 

  Device can  be cleaned  by  means of wet cloth and mild detergent  without abrasive components. In 

particular  do  not  clean  with  alcohols,  solvents,  petrol,  disinfectants,  acids,  rust  removers,  etc. 
Damages  resulting  from  improper  maintenance  and  usage  are  not  covered  by  manufacturer 
warranty. 

3.

 

O

PERATION SCENARIOS

 

The terminal  when connected to MC16  access controller can  be  at the same time used  for access control 
and Time&Attendance. The example of connection diagram for such scenario is shown in fig. 6 where inputs 
and outputs from MC16 board are used and in fig. 7 where inputs and outputs from 

–IO version terminal are 

used.  The  terminal  can  also  operate  with  MC16  controller  using  MCX2D/MCX4D  expanders  as  in  case  of 
M16-PAC-KIT  series.  Various  scenarios  of  operation  with  MC16  controllers  are  presented  in  AN002 
application note. 
 

 

Fig. 6 Typical connection diagram for the terminal and MC16 access controller 

Summary of Contents for MCT12E

Page 1: ...Roger Access Control System MCT12E Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Page 2: ...ly IO versions Power supply The terminal requires power supply voltage in range of 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or f...

Page 3: ...matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twiste...

Page 4: ...icates access granting LED SYSTEM Orange LED indicates card reading and can signal other system functions including device malfunction Note Synchronic pulsing of LED indicators signifies lost communic...

Page 5: ...rds EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical characteristics...

Page 6: ...85 bus line B CLK White Green CLK line DTA Green Yellow DTA line TMP Yellow Pink Tamper contact TMP Grey Grey Tamper contact IO1 Yellow brown IO1 output line IO2 Green brown IO2 output line REL1 NC Gr...

Page 7: ...MCT12E Operating Manual 05 10 2020 7 14 Fig 5 MCT12E installation...

Page 8: ...must be connected with any wire Device can be cleaned by means of wet cloth and mild detergent without abrasive components In particular do not clean with alcohols solvents petrol disinfectants acids...

Page 9: ...MCT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 En...

Page 10: ...h readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default value...

Page 11: ...disabled Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comm...

Page 12: ...the next digit Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3...

Page 13: ...5 bus between controller and reader IP Code IP65 Environmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dim...

Page 14: ...ctric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste cont...