12
GB
CV Name
Description
Value
range
Works
value
47 Speed correction
Speed correction forwards
Correction factor = value from CV64/128
00 – 63
32
48 Speed correction
Speed correction reverse
Correction factor = value from CV64/128
00 – 63
32
49 Extended
configuration
You can activate the support for the braking
sectors or deactivate the load control
If the Motorola** data format is deacti-
vated via Bit 3 and the DCC format via
Bit 4, the decoder does not receive any
more driving commands and can only be
programmed.
00 – 255
32
50 Dimmer
Determines the brightness of the light outlets
00 – 32
32
51 Analogue mode of
operation
Analogue mode of operation settings
01 – 03
3
Bit Description
Value
0
AC-detection off
AC-detection on
0
1
1
DC-detection off
DC-detection on
0
2
2
Lighting switchable
Lighting permanent
0
4
Bit Description
Value
0
Load control active
Load control inactive
0
1
2
Brake to 0 in the braking sector
Brake to driving stage in accor-
dance with CV52
0
4
3
Motorola** data format active
Motorola** data format inactive
0
8
4
DCC data format active
DCC data format inactive
0
16
5
Light dimming on
Light dimming off
0
32
6
Do not swap the light connections
(front/rear)
Swap the light connections
0
64
7
Braking only with brake signal
Braking with analogue voltage
0
128
8010732920 VII_2009.indd 12
13.08.2009 09:10:56